Large round cable entry ports
•
Taking a cable with 120cm of cable jacket removed.
•
Feed the cable through the plastic compression nut.
•
Then feed on the 52mm compression ring followed by the rubber seal and a further 52mm compression ring
•
Push the cable through the required round port.
•
Secure the cable ends to the internal cable clamp.
•
Secure the strength member to the end of the cable clamp.
•
•
If the round port is not to be used insert the blanks provided
•
And seal with the compression gland as above
With the cable fully secured push the rubber seal into the round port followed by the compression gland and tighten the
plastic compression nut.
Fibre routing
Mounting options
Wall
Aerial
Manhole
Direct Burial
•
Cables should be routed to the side channels of the splice trays, all Fibre should be protected by transit tube of spiral wrap
•
Bare fibres are routed around the splice tray allowing for additional length of fibre for rework. each fibre is then spliced and
(supplied) and fibres fed to each tray as required
splice protectors placed in to the space provided.
Accessories Included
Rubber seal and compression ring 12mm to 17mm
x 4
Rubber seal and compression ring 8mm to 12mm
x 4
Plastic
blanking
plug
x
4
Wall
fixings
x
1
set
Splice
protectors
48
to
144
Allen
Key x
1
Sealing
putty
x
1
reel
Pole / wall mounting bracket
x 1
Nylon
tie x
10
PVC
tape x
1
reel
MF1501/10/18