13
Installer Programmable Features (cont’d)
Feature #5 Satellite Relay Port Green Wire Function
Starter
(press “
lock
” button to program)
- DEFAULT
Pulse After Engine Start
(press “
unlock
” button to program)
Status
(press “
trunk
” button to program)
Domelight
(press “
start
” button to program)
This feature changes the operation of the green wire (negative) on the satellite relay
port. This gives you the flexibility to accommodate certain vehicles that require any
out-of-the-ordinary pulses or remote start timing.
Starter
setting operates as a secondary START output. This will have the same
pulse timing as the large Violet wire on the main harness.
Pulse After Start
setting will give a 0.8 second pulse immediately after the engine
starts and is running.
Status Output
setting will behave like the ignition output except it turns on 1.5
seconds earlier than the primary ignition output..
Domelight
setting turns the output on for 30 seconds after unlocking or after turning
the ignition key off.
Feature #6 Satellite Relay Port Blue Wire Function
Status
(press “
lock
” button to program)
- DEFAULT
Ignition
(press “
unlock
” button to program)
Status
- operates like the PInK ignition output except it turns on 1.5 seconds earlier
than the PInK ignition #1 output. This is best for activating bypass kits.
Ignition
- operates with the same timing as the PInK ignition #1 output.
Feature #4 Gasoline Or Diesel Engine
Gasoline
(press “
lock
” button to program)
- DEFAULT
Diesel 15 Sec. Delay
(press “
unlock
” button to program)
Diesel 20 Sec. Delay
(press “
trunk
” button to program)
Diesel 30 Sec. Delay
(press “
start
” button to program)
This feature changes the system’s timing of the ignition and starter output sequence
for gas or diesel engines. gasoline: the starter output will occur 3 seconds after the
ignitions turn on. when in “Tachless” mode, the engine running status is determined
10 seconds after starting. Diesel: the starter output will occur 15, 20, or 30 seconds
after the ignitions turn on (allows for glow plug warming). when in “Tachless” mode,
the engine running status will be determined 40 seconds after cranking.
“Tach Wire”
monitors the “Violet/white wire” (see the installation manual for the
Tach Learn Procedure). It will crank the engine until a tach signal is detected (3
seconds max).
“Data Tach”
mode operates just like the “Tach wire” setting except it takes its
reading from the D2D data port instead of using the Violet/white wire. Before using,
make sure this function is supported by the Databus Interface module.
“Crank Only”
AKA “blind start” is similar to the “Tachless” settings however, it only
makes one start attempt and does not monitor engine running conditions. This is
useful for many “push-to-start” vehicles.
Содержание RS-350-EDP
Страница 16: ...Back Cover Color cover is in a separate file...