14
Installer Programmable Features (cont’d)
Feature #8 Doorlocking Output Functions
0.8 Second Outputs
(press “lock” button to program)
- DEFAULT
3 Second Outputs
(press “unlock” button to program)
Double 0.8 Sec Unlock Output
(press “trunk” button to program)
Total Closure Lock Output
(press “start” button to program)
This single feature gives the installer several needed options, to match the system’s
doorlocking outputs to suit different vehicle requirements.
0.8 Second Outputs
on both Lock and Unlock outputs.
3 Second Outputs
on both Lock and Unlock outputs.
Double 0.8 Sec Unlock Output
w/ single 0.8 sec Lock output.
Total Closure Lock Output
gives a 28 second Lock output and a 0.8 second
unlock output.
Feature #10 Turbo Timer
Off
(press “lock” button to program)
- DEFAULT
Run 1 Minute
(press “unlock” button to program)
Run 2 Minutes
(press “trunk” button to program)
Run 3 Minutes
(press “start” button to program)
This feature when turned on configures the system to automatically keep the engine
running briefly after it is turned off. This operation is designed specifically for ve
-
hicles having turbocharged engines. This feature should only be programmed by the
installer, and the operation of this feature depends on the correct connection of the
neutral safety wire to the vehicle’s parking brake. Please refer to the “Black/white
wire” in the installation manual for the proper connection of this important wire.
Feature #11 Manual Transmission Remote Start
On
(press “lock” button to program)
Off
(press “unlock” button to program)
- DEFAULT
Enabling this feature requires a “setup” procedure to be performed that ensures the
transmission is in neutral before remote start can be performed. See page 7 for
more information.
Feature #9 Remote Start Lock Control
Off
(press “lock” button to program)
- DEFAULT
Lock After Start
(press “unlock” button to program)
Unlock before start
(press “trunk” button to program)
Unlock Lock After Start
(press “start” button to program)
This feature allows for OEM alarm/lock control in relation to remote start operations
thus eliminating extra wiring.
Feature #7 Extended Starter Cranking Time
0.7 Second
(press “lock” button to program)
- DEFAULT
1.00 Second
(press “unlock” button to program)
1.5 Seconds
(press “trunk” button to program)
2.25 Seconds
(press “start” button to program)
This feature determines the crank time of the 1st start attempt when in “Tachless”
mode. If the engine doesn’t start on the first attempt, it will retry up to 3 more times
extending the crank time by an additional 0.2 second with each attempt..
Содержание RS-340-EDP