SOFTENER INSTALLATION AND USER GUIDE
BARRIE • ONTARIO • CANADA 705.733.8900 WWW.EXCALIBURWATER.COM
1.9)
Drain Line
•
The ½” tubing must be used for drain line.
•
Leave minimum of 6” gap between flow control fitting and solder joints. The gap less than this
can damage the flow control.
•
If the drain line is elevated and then emptied into the drain below the level the of control valve
then 7” loop should make at the end of drain line.
•
The air gap between the drain and the end of the drain line must be twice the diameter of the
tube.
•
The drain line must be clamped or strap tied at the end to secure in position.