![Excalibur Water Systems EWS SUS24BF Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/excalibur-water-systems/ews-sus24bf/ews-sus24bf_installation-and-user-manual_2449281011.webp)
10
SOFTENER INSTALLATION AND USER GUIDE
BARRIE • ONTARIO • CANADA 705.733.8900 WWW.EXCALIBURWATER.COM
2)
CONTROL VALVE PROGRAMMING
2.1)
Regeneration Screens
2.2)
Button Operation
2.3)
Setting Time of Day
Regen Screen
•
Displays the time remaining in the current cycle.
•
Displays the cycle name and sequence number.
•
Pressing REGEN advances to the next cycle.
Scrolls to the next display.
•
Pressing once and releasing will schedule a regeneration at the preset delayed regeneration time.
•
Pressing again and releasing will cancel the delayed regeneration.
•
Pressing and holding for 3 seconds will initiate an immediate regeneration
•
Pressing while in regeneration will advance to the next cycle.
•
Pressing in the program levels will go backwards to the previous screen
Change Variable being displayed.
Holding for 3 seconds initiates a control reset. The software version is displayed and the
piston returns to the home/service position, resynchronizing the valve.
Step 1
: - Push NEXT until time of day screen is displayed. Press and
hold
▼
until SET TIME is displayed and the hour flashes once.
Step 2
: - Press
▲
or
▼
until the correct hour is displayed. Then press
NEXT button.
Step 3
: - The minutes will flash. Press
▲
or
▼
until the correct
minute is displayed. Press NEXT to return to the User Displays.
Time of day should only need to be set if: -
•
power outage lasts more than 8 hours with good battery
•
battery is depleted and power outage occurs
•
when daylight saving time begins or ends.
Regeneration occurs automatically if volume capacity drops below the reserve capacity automatically
predicted by Control Valve or the has control valve reached 14 number of days since last regeneration.