Exar SP336E Скачать руководство пользователя страница 6

 

 

 

 

Table 2 is a matrix describing all the possible modes for the SP366 and lists the jumper settings 
for each mode. The Driver inputs, SLEW, MODE and the Loop back are all define an operating 
mode. The modes are listed in the first column. The inputs to T1_In (TP32 & TP44), T2_In (TP31 
& TP43), T3_In (TP30 & TP42) and T4_In (TP14 & TP8) can be made using the 50 Ohm 
terminated resistor. Set the SP336 for the mode to be tested. Channels can also be connected 
high or low individually by the test points mention above and reference in Table 1. 
 
Slew rate control for the SP336E drivers is logic selectable using the SLEW pin which is 
connected to SW3-4 “1”. Connecting SW3-4 (Left) provides high speed and no slew limiting 
while SW3-4 “0” (Right) limits the driver slew rate. 
 
Local loop back diagnostic mode for RS232 is provided “on chip” by using logic programmable 
mode 000. Local loop back testing for RS485/422 mode is also provided on the evaluation board 
and can be implemented using the headers (Sw3-1 is Mode 0, SW3-2 is Mode 1 & SW3-3 is 
Mode 2). Set mode input logic to 101 to define RS485/422 mode. Follow Table 4 and jumper 
from test point to test point to Loopback. 
Reference to Table 4: 
 

Table 4 

Device 

Signal 

Device 

Signal 

U6-6 

T1_out TP17 

U6-15 

R1_in TP40 

U6-7 

T2_out TP21 

U6-16 

R2_in TP39 

U6-4 

T1_out TP16 

U6-17 

R3_in TP38 

U6-3 

T1_out TP15 

U6-18 

R4_in TP37 

 

 

 

 

Отзывы: