![EWT CS 2 Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/ewt/cs-2/cs-2_operators-manual_2448442043.webp)
TROUBLESHOOTING
Symptom
Possible Causes
Corrective Action
Vacuum will not
operate.
Dust comes from
motor cover.
Reduced
efficiency and
motor/speed
vibration.
1) No power supply.
2) Malfunction of electric cable,
switch or motor.
3) Container full of liquid.
3) Empty container.
1) The dust filter is missing or
damaged.
1) Dust bag full.
2) There is a blockage in the
nozzle, the hose, or the
container inlet, or the dust
filter is blocked by fine dust.
1) Check the nozzle, the hose, and the
container inlet for blockage. Take off
the dust filter, and wash and clean it.
Reuse it when it is dry.
It is recommended to use a new dust
filter.
1) Replace dust bag.
1) Attach or replace dust filter.
1) Check power supply – cable,
breakers, fuses.
2) Have a specialist check and repair or
replace the defective component.