1. Product Specifications  

1-1. 

Specifications of the Indicator

  

 Name 

Gas Leak Detector (MODEL:EW401) 

Detector Gases 

LPG LNG City Gas (Methane, Butane, Propane) 

Combustible Gas 

Power  

AC 220V. 60㎐ (AC 230V 50㎐ AC110V/ 50㎐ option) 

Power Consumption  

Normal: 2.5W. Alarm: 3W 

Operating Temperature Range 

 and Humidity 

-10℃~ 50℃, 0~95% RH 

Readout Range 

0 ~ 100% LEL 

Alarm Point 

Within 25% (user adjustable*Variable setting) 

Response Time 

Within 20 seconds 

Visual Alarm and Audio Alarm 

Flickering of LED LAMP (yellow) and above 70Db  of buzzer sound 

Operating Indicator 

Lighting of LED LAMP (green)  

Trouble Indicator 

Lighting of LED LAMP (Red)  

Warm up Time 

60 seconds 

Connection Cable 

VCT or CVVS  above O.75mm SQ Use over

 

Dimension  

114*250*80 

Outer Output 

DC 12V(20~30mA Output). Contact point of non-voltage  

contact point NO.NC.COM(Relay contact point)  

Capacity of Contact Point 

AC 110/1A. DC 12~24 2A 

Weight 

Some 1,840g 

1-2. 

Specifications of the Detector

  

Type  

Expansion Type 

Detector Gases  

LPG LNG City Gas (Methane, Butane, Propane) Combustible Gas  

Sensor Type 

Catalytic, Combustion (Hot-wire type) Diffusion Type  

Operating Temperature Rang  

and Humidity 

-20℃~ 50℃, 0~95% RH 

Explosion-proof Type 

ExdⅡBT₄ 

Cable Connector 

Inside Dia 16mm/ Outer Dia 23mm 

Dimension 

137*142*75 

Weight 

1,036g 

Readout Range 

0~100%(LEL) 

Response Time 

Within 20 seconds 

TONGPRASERTCHAI CO.,LTD.

Содержание EW-401

Страница 1: ...GAS LEAK DETECTOR MODEL EW 401 Explanations EWOO ENGINEERING CO LTD T O N G P R A S E R T C H A I C O L T D ...

Страница 2: ... 1 2 Specifications of the Detector 2 Function of Each Device and Title Explanations 2 1 Indicator 2 2 Detector 3 Wiring Diagram 4 Operation System Diagram 5 Installation Place and Installation Drawing 6 Operation Method and Instructions T O N G P R A S E R T C H A I C O L T D ...

Страница 3: ...ble Indicator Lighting of LED LAMP Red Warm up Time 60 seconds Connection Cable VCT or CVVS above O 75mm SQ Use over Dimension 114 250 80 Outer Output DC 12V 20 30mA Output Contact point of non voltage contact point NO NC COM Relay contact point Capacity of Contact Point AC 110 1A DC 12 24 2A Weight Some 1 840g 1 2 Specifications of the Detector Type Expansion Type Detector Gases LPG LNG City Gas ...

Страница 4: ...be reversed when reversion switch is pushed after Alarm level meter buzzer relay it drops on the densitometer Buzzer stop Lamp Gas Density Indicator In case of pushing the switch against Expanded gas density is marked by lamp level meter Alarm buzzer turns off and lamp around LEL Indication switch and etc turn off Table indicating lamp level meter and LEL conversion Buzzer Stop Switch In case of p...

Страница 5: ... Filter Ground earth Sensor protection filter bronze 300mesh M4 6mm Cover Fixing bolt Molded Cover The bolt for fixing cover and body of Detector Cable grand Molded Body Cable Insert Device Wire Cable pipe or fiexible screw Female screw VCTF 0 75x3C Blue Brown Green T O N G P R A S E R T C H A I C O L T D ...

Страница 6: ...are connected at ordinary times In case of alarming COM terminal and NO terminal are connected Sensor Connection Terminal Blue Brown Green It is connected to be matched with wire colors arranged in detection device Blue Electric Line Brown Electric Line Green Signal Line Signal Output In case of alarming it can be used for shut off device or other various devices with DC12V 30mA output T O N G P R...

Страница 7: ...4 Operation System Diagram T O N G P R A S E R T C H A I C O L T D ...

Страница 8: ...teristics of gas instructions structure of each device and etc 3 As for installation height of detection device if the gas heavier than air it shall be installed within 30cm above the floor while if the one lighter than air it shall be installed within 30cm below the ceiling 4 Installation place for receiver device of gas leak alarm device shall be installed in the proper place to take every measu...

Страница 9: ... after finishing the connection of receiver device and detection device 2 In case power supply switch turns on power supply lamp will be flickered for some one minute and in case early stabilization time is passed power supply lamp will stops flickering and be lighted and circuit will be operated in normal way 3 In case detection device is disconnected buzzer is sounded and trouble signal is light...

Страница 10: ...tatus Instructions 1 Optional disassembly repair or alteration is not allowed by an person except the relevant personnel of our company 2 As for the product equipped with earthing terminal earthing line shall be surely installed 3 In case of connecting receiver device and detection device the same manufacturing number shall be connected 4 To confirm the voltage before installation to match 110V 22...

Отзывы: