Machine description – quick overview
Machine control – Operating elements
099-005224-EW501
08.11.2011
23
Item Symbol Description
0
6
Button, Gas test
The welding voltage and wire feed remain off when testing and setting the gas flow.
Pressing the key button once causes shielding gas to flow for approx. 25 seconds. The
button can be pressed again at any time to cancel the process.
7
Button, Wire inching
For inching the wire electrode when changing the wire spool
(speed = 6.0 m/min, constant).
The welding wire is inched into the tube package with the current off and without gas
being expelled.
This ensures a high degree of safety for the welder by preventing accidental ignition of
the arc.
8
Upper, display
Displays welding voltage or person who designated the runtime parameters
9
Signal light, HOLD
Lit:
Display shows the last parameters used for welding.
Not lit: Display shows the setpoint values or current values during welding.
10
Signal light, Wire speed
Lights when the wire speed is shown on the display.