Design and function
Machine configuration menu
72
099-000099-EW501
29.08.2014
Display
Setting/selection
Exit the menu
Exit
Torch configuration menu
Set welding torch functions
Torch mode (factory setting 1)
Up-/Down speed
Increase value
= rapid current change (factory setting 10)
Reduce value
= slow current change
Setting the first increment
Setting: 1 to 20 (factory setting 1)
Machine configuration
Settings for machine functions and parameter display
Welding current display (ignition, secondary, end and hotstart currents)
• Pro = welding current display as a percentage of the main current (factory setting)
• Abs = absolute welding current display
Non-latched operation (C version)
• on = on
• off = off (factory setting)
Power display switching (MMA)
• on = actual value display
• off = setpoint value display (factory setting)
Pulses in the upslope and downslope phases
The function can be switched on or off
Machine configuration (part two)
Settings for machine functions and parameter display
Ramp function Remote control RTF 1
The ramp function can be switched on and off
spotMatic
Variation of operation mode spotArc, ignition with workpiece contact
• on = on
• off = off (factory setting)
Setting spot time
• on = Short spot time (5 ms - 999 ms, 1 ms- steps)
• off = long spot time (0,01 s - 20,0 s, 10 ms- steps)
Setting process activation
• on = Separate process activation:
The welding process has to be reactivated for every arc ignition by pressing the torch
trigger.
• off = Permanent process activation:
The welding process is activated by pressing the torch trigger once. The following arc
ignitions are initiated by shortly touching the tungsten electrode against the
workpiece.
Torch cooling mode
• AUt = automatic operation (ex works)
• on = permanently switched on
• off = permanently switched off
Welding torch cooling system pre-flow time
Setting 1
–60 min. (ex works 5)
Expert menu