Design and function
PC interface
28
099-000235-EW501
17.12.2020
5.6 PC interface
Equipment damage or faults may occur if the PC is connected incorrectly!
Not using the SECINT X10USB interface results in equipment damage or faults in signal trans-
mission. The PC may be destroyed due to high frequency ignition pulses.
• Interface SECINT X10USB must be connected between the PC and the welding machine!
• The connection must only be made using the cables supplied (do not use any additional ex-
tension cables)!
PC300.Net welding parameter software
Set all welding parameters on the PC and simply transfer to one or more welding machines (accessory,
set consisting of software, interface, connection leads)
• Manage up to 510 JOBs
• Exchange JOBs with the welding machine
• Online data communication
• Default settings for welding data monitoring
• Always up-to-date thanks to standard update function for new welding parameters
• Data backup by easy communication between power source and PC
5.6.1 Connection
Figure 5-14
Item Symbol Description
0
1
Connection socket (9-pole) - D-Sub
PC interface
2
Connection cable, 9-pole, serial
3
SECINT X10 USB
4
USB connection
Connecting a Windows PC to SECINT X10 USB
5
Windows PC
5.7 Interfaces for automation
Damage to the machine due to improper connection!
Unsuitable control leads or incorrect connection of input and output signals can cause damage
to the machine.
• Only use shielded control leads!
• If the machine is to be operated with control voltages connection via suitable isolation ampli-
fiers is required!
• To control the main or secondary current via control voltages, the relevant inputs must be
enabled (see specification for activation of control voltage).