Technical data
Taurus XQ 505 Synergic
099-005664-EW501
22.09.2021
47
8.4 Taurus XQ 505 Synergic
MIG/MAG
MMA
TIG
Welding current (I
2
)
5 A to 500 A
Welding voltage according to standard (U
2
)
14,3 V to 39 V
20,2 V to 40 V
10,2 V to 30 V
Duty cycle DC at 40° C
[1]
500 A (40%)
430 A (60%)
370 A (100%)
Mains voltage
[2]
/ Tolerance / mains fuse
[3]
3 x 380 to 400 V / -25 % to +20 % / 3 x 25 A
3 x 440 to 480 V / -25 % to +15 % / 3 x 20 A
Frequency
50/60 Hz
Open circuit voltage (U
0
)
82 V to 98 V
82 V to 102 V
max. Connected load (S
1
)
24,6 kVA
25,3 kVA
19,0 kVA
Generator rating (Rec.)
34,2 kVA
Power consumption P
0
[4]
21 W
Maximum mains impedance (@PCC)
[5]
96 mOhm
Cos φ / efficiency
0,99 / 90 %
Protection class / Overvoltage category
Ⅰ
/
Ⅲ
Contamination level
3
Insulation class / protection classification
H / IP 23
Residual current circuit breaker
Type B (recommended)
Noise level
[6]
<70 dB(A)
Ambient temperature
[7]
-25 °C to +40 °C
Machine cooling / Torch cooling
Fan (AF) / gas or water
Mains connection cable
H07RN-F4G4
Workpiece lead (min.) / EMC class
95 mm
2
/ A
Safety marking
/ /
Standards used
See declaration of conformity (appliance documents)
[1]
Load cycle: 10 min. (60 % DC
≙
6 min. welding, 4 min. pause)
[2]
Multi-voltage device - Adjusting the power source to the mains voltage
[3]
Safety fuses are recommended DIAZED xxA gG. When using automatic cutouts, the "C" trigger chara-
cteristic must be used.
[4]
Power in idle mode without wire feeder.
[5]
This welding equipment does not comply with IEC 61000-3-12. When connecting a welding machine
to a public low-voltage supply system, the manufacturer or operator has to consult the electricity utili-
ties to make sure the welding machine may be connected.
[6]
Noise level during idle mode and operation under standard load according to IEC 60974
‑
1 at the maxi-
mum operating point.
[7]
Ambient temperature dependent on coolant! Observe coolant temperature range!