Design and function
Machine configuration menu
44
099-005221-EW501
05.09.2016
5.6
Machine configuration menu
5.6.1
Selecting, changing and saving parameters
ENTER (Enter the menu)
• Switch off the machine at the main switch.
• Press and hold down the "Welding procedure" push-button and switch the machine on again
at the same time.
NAVIGATION (Navigate the menu)
• Select parameters by turning the "Welding parameter setting" rotary knob.
• Set or change the parameters by turning the "Welding voltage" rotary knob.
EXIT (Exit the menu)
• Press the "Push-button, parameter selection right" push-button (switch machine off and on
again).
Enter
Exit
+
l
0
l
0
Figure 5-27
Display
Setting/selection
Lead resistance 1
Lead resistance for the first welding circuit 0
mΩ–60 mΩ (8 mΩ ex works).
Only qualified service personnel may change the parameters!
Time-controlled power-saving mode
> see 5.6.2 chapter
• ---------- 5 min.–60 min. = time until activation of power-saving mode when inactive.
• ---------- off = switched off
Service menu
Modifications to the service menu may only be carried out by authorised maintenance
staff!