Design and function
MIG/MAG welding
34
099-005214-EW501
19.05.2011
5.7.6
Welding task selection
5.7.6.1
Basic welding parameters
Operating
element
Action Result
MIG / MAG
GMAW
Welding process selection
Signal light
MIG / MAG
GMAW
on.
5.7.6.2
Operating mode
Operating
element
Action Result
Operating mode selection
The signal light indicates the selected operating
mode.
Non-latched
operation
Latched
operation
No change
The operating point is set with the wire speed and arc length rotary dials.
The operating point setting can also be specified using accessory components such as remote control,
welding torch, etc.
5.7.6.3
Setting the operating point (welding output)
The M3.77 control works according to the twin-knob operation principle. To set the operating point, only
the wire speed and the welding voltage need to be set according to the material and the electrode
diameter.
Operating
element
Action Result
m/min
Wire speed setting
0,5 bis 24 m/min
Welding voltage setting
10 V bis 49,8 V
5.7.6.4
Choke effect / dynamics
DY N
m /m in
Figure 5-10
Display Setting/selection
Dynamics setting
40: Arc harder and narrower
-40: Arc softer and wider