Design and function
Machine configuration menu
58
099-000188-EW501
22.02.2016
5.13.6 TIG antistick
The function prevents uncontrolled re-ignition following the sticking of the tungsten electrode in the weld
pool by switching off the welding current. In addition, wear at the tungsten electrode is reduced.
The function takes effect in the main current phase of the latched operating mode- See 5.8.6.3 Latched
mode chapter.
The 3rd and 4th cycle are omitted and the welder starts the new process with the 1st cycle. The user can
switch the function on or off (see the procedure below).
ENTER
EXIT
NAVIGATION
+
l
0
Figure 5-31
Display
Setting/selection
Lock JOB menu
Protect welding parameters from unauthorised access.
Settings
Settings for machine functions and parameter displays.
TIG antistick- See 5.13.6 TIG antistick chapter
function active (factory setting).
function inactive.
Exit the menu
Exit