Machine description
– quick overview
Machine control
– Operating elements
16
099-000188-EW501
22.02.2016
4.3
Machine control
– Operating elements
Figure 4-3
Item Symbol
Description
0
1
Welding data display (3-digit)
Displays the welding parameters and the corresponding values- See 5.7 Welding data
display chapter
2
Error/status displays
---------- Collective interference signal light
-------- Water deficiency signal light (welding torch cooling)
--------- Excess temperature signal light
--------- sign signal light
VRD ----- voltage reduction device (VRD)
3
AMP
Main current signal light
Imin to Imax (1 A increments)
4
AMP%
Secondary current (TIG)
Setting range 1 % to 100 % (1 % increments). Percentage of the main current.
5
Welding parameter setting rotary dial
Setting currents, times and parameters.
6
Select welding parameters button
This button is used to select the welding parameters depending on the welding process
and operating mode used.
7
sec
Down-slope time (TIG)
The down-slope time can be set separately for non-latched and latched. Setting range
0.00 s to 20.0 s (0.1 s increments).