Machine description
Machine control – Operating elements
20
Item No.: 099-002046-EWM01
4.3.1
Welding data display
The relevant value will be displayed on the welding data display depending on the parameters selected
(currents or times). The display switches back to the setpoint value for the welding current after approx. 5
seconds.
Advanced parameters are shown with an alternate display of the welding parameter and its value
(abbreviation of parameter is displayed for approx. 2 sec. > parameter value is on for approx. 2 sec.). The
display switches back to the setpoint value for the welding current after approx. 60 seconds.
In addition, in the event of functional errors the relevant error codes are shown on the display (see
“
Operating problems, causes and remedies” chapter
).