MMA welding
099-005313-EW501
02.09.2015
53
5.8.2
Welding task selection
• Select MMA JOB 128- See 11.1 JOB-List chapter.
It is only possible to change the JOB number when no welding current is flowing.
Operating
element
Action
Result
Display
1 x
Select JOB list
(LED
is on)
Set JOB number.
Wait 3 s until the setting has been applied.
5.8.3
Welding current setting
Set the welding current with the rotary dial for the welding parameter settings.
Operating
element
Action
Result
Display
Set welding current.
current nominal
value
5.8.4
MMA welding data display
Diagram 5-22
The button for the welding parameter display mode is next to the display.
Each time the button is pressed it switches between welding current and welding voltage.
The display shows:
• Nominal values (before welding)
• Actual values (during welding)
• Hold values (after welding)
Parameter
Nominal values
Actual values
Hold values
Welding current
Welding voltage
The display switches back from hold values to actual values for approximately 5 s after welding is