Design and function
MIG/MAG welding
42
099-005313-EW501
02.09.2015
5.7.9.3 Spot time
Select the respective operating mode before setting the spot or pause time.
Operating
element
Action
Result
Display
n x
Selecting the parameter to be set
The LED indicates the parameter selected.
Parameter value set
Choke effect/dynamics
Gas post-flow time
Spot time
Pause time (interval operation)
Setting the stop time.
Setting range:
0.1 s to 20.0 s in increments of 0.1 s
5.7.9.4 Pause time (interval operation)
Operating
element
Action
Result
Display
n x
Selecting the parameter to be set
The LED indicates the parameter selected.
Parameter value set
Choke effect/dynamics
Gas post-flow time
Spot time
Pause time (interval operation)
Setting the pause time.
Setting range:
0.1 s to 20.0 s in increments of 0.1 s