Functional characteristics
Interfaces
64
Item No.: 099-005073-EWM01
5.5.2
RINT X11 robot interface
The standard digital interface for automated applications
(optional, retrofitting on the machine or external fitting by the customer)
Functions and signals:
• Digital inputs: Start/stop, operating mode, job and program selection, inching, gas test
• Analogue inputs: Control voltages for welding output, correction, dynamics
• Relay outputs: Current flows, welding data monitoring, ready for welding, etc.
5.5.3
BUSINT X10 Industrial bus interface
The solution for easy integration into automated production lines, with for example
• Profi
bus
• CAN bus and
• Interbus
systems
(optional, external installation by customer)
5.5.4
DVINT X11 Wire feed interface
For the flexible connection of special wire feed units (optional, retrofitting on the machine or externally by
the customer).
As examples: Binzel (APD system), Dinse wire feed systems.
5.5.5
PC Interfaces
PC 300 welding parameter software
Create all welding parameters quickly on the PC and easily transfer them to one or more welding
machines (accessories: set consisting of software, interface, connection leads).
Q-DOC 9000 welding data documentation software
(Accessories: set consisting of software, interface, connection leads)
The ideal tool for welding data documentation of, for example:
welding voltage and current, wire speed and motor current.
WELDQAS welding data monitoring and documentation system
Network-compatible welding data monitoring and documentation system for digital PHOENIX and
TETRIX machines
5.5.6
Setting options, internal
5.5.6.1
Switching between Push/Pull and intermediate drive
The plugs are located directly on PCB M3.70 in the wire feed unit.
Plug Function
on X24
Operation with Push/Pull welding torch (factory setting)
on X23
Operation with intermediate drive