Functional characteristics
MIG/MAG welding
Item No.: 099-005073-EWM01
55
5.2.11.16
JOB list switching (P12)
Factory setting for parameter P12
• PHOENIX
301,351,421 PROGRESS KG
0
• PHOENIX 333 PROGRESS KG
1
• PHOENIX 303 PROGRESS coldArc KG
1
• PHOENIX PROGRESS 4.4L
0
• PHOENIX PROGRESS DRIVE 4L coldArc
1
Value Designation
Explanation
0 Task-oriented
JOB list
The JOB numbers are sorted by welding wires and shielding gases.
JOB numbers may be skipped during selection where relevant.
1
Actual JOB list
JOB numbers correspond to the actual memory cells. Each JOB can be
selected; no memory cells are skipped during selection.
2
Actual JOB list,
JOB changeover active
As for the actual JOB list. JOB changeover is also possible with
accessory components, such as the PowerControl 2 torch.
When switching between the actual and task-oriented JOB lists, the assignment of the welding
tasks to the JOB numbers will change!
•
The "JOB list" sticker is no longer valid!
In the appendix you will find pictures of both JOB lists. See "JOB list sticker" chapter.
All JOB number specifications in these instructions relate to the factory settings.
5.2.11.17
Creating user-defined JOB lists
A consecutive memory range where accessories such as the PowerControl 2 torch can be used to
switch between JOBs will be created.
• Set special parameter P12 to "2".
• Set "Program or Up/Down function" changeover switch to "Up/Down" position.
• Select an existing JOB which is closest to the required result.
• Copy JOB to one or more target JOB numbers.
If any JOB parameters need to be changed, select the target JOBs in sequence and change the
parameters individually.
• Set special parameter P13 to the lower limit and
• Set special parameter P14 to the upper limit of the target JOBs.
• Set "Program or Up/Down function" changeover switch to "Program" position.
JOBs can be changed over in the specified range using the accessory component.