Design and function
Setting the welding smoke flow rate
30
099-510058-EW501
27.09.2021
5.7 Setting the welding smoke flow rate
5.7.1 Measurement preparation
• Before measuring the flow rate, it is necessary to measure the amount of shielding gas.
• The quantity of shielding gas is measured at the gas nozzle of the welding torch and is set either di-
rectly on the pressure regulator or, if available, on the gas control unit of the wire feeder or power
source.
• Connect the welding torch to the welding machine or wire feeder.
• Connect the welding fume extractor hose to the welding torch using an adapter
> see 9 chapter
.
• Connect the welding fume extractor hose to the extraction system
The welding smoke flow rate can be influenced by using the bypass slider.
The illustration serves as an example only.
Figure 5-20
Item Symbol Description
0
1
Bypass slider, extraction capacity
2
Welding fume extractor
3
Nozzle holder with diaphragm grommet
4
Extraction nozzle
5
Scale
Welding smoke flow rate (values
> see 8 chapter
)
6
Endcap
7
BG AFM - Airflow meter assembly
> see 9 chapter
8
O-ring
Floater
9
Floater
10
Measuring tube