Rectifying faults
Warnings
099-0M37XS-EW501
31.8.2022
49
Error 57: Slave tacho error
Category B
Fault in the wire feeder (slave drive).
Check the connections (connectors, lines).
Permanent overload of the wire drive (slave drive).
Do not lay the liner in tight radii.
Check the liner for smooth movement.
Error 58: Short circuit
Category B
Short circuit in the welding circuit.
Eliminate the short circuit in the welding circuit.
Place the welding torch on an insulated surface.
Error 59: Incompatible machine
A machine connected to the system is not compatible.
Disconnect the incompatible machine from the system.
Error 60: Incompatible software
The software of a machine is not compatible.
Disconnect the incompatible machine from the system
Request service.
Error 61: Welding monitoring
The actual value of a welding parameter is outside the specified tolerance range.
Maintain the tolerance ranges.
Adjust the welding parameters.
Error 62: System component
The system component was not found.
Request service.
Error 63: Mains voltage error
Operating and mains voltage are incompatible.
Check or adjust the operating and mains voltage.
[1]
See technical data for values and other switching thresholds.
7.3 Warnings
Depending on the display options of the machine display, a warning message is displayed as follows:
Display type - machine control
Display
Graphic display
two 7-segment displays
one 7-segment display
The cause of the warning is indicated by a corresponding warning number (see table).
• In case of multiple warnings, these
are displayed in sequence.
• Document machine warning and inform service personnel, if required.
Warning
Potential cause / remedy
1
Excess temperature
A shutdown is imminent due to excess temperature.