5.3.1
Adding coolant
After the initial filling, wait for at least one minute when the machine is switched on so that the
hose package is filled with coolant completely and without bubbles.
With frequent changes of torch and during the initial filling process, the cooling unit tank should
be topped up as necessary.
The unit is supplied ex works with a minimum level of coolant.
Figure 5-5
Item Symbol
Description
0
1
Coolant tank cap
2
Coolant filter sieve
3
Coolant tank
4
"Min" mark
Minimum coolant level
• Unscrew and remove the coolant tank sealing cover.
• Check filter sieve insert for dirt, clean if necessary and reinsert into position.
• Top up coolant to the filter sieve insert, close sealing cover again.
The level of coolant must never fall below
the “min” mark.
If there is less coolant in the coolant tank than the minimum required you may need to vent the
coolant circuit. In this case the welding machine will automatically shut down the coolant pump
and signal an error, > see 7.2 chapter.
5.3.2
Welding torch connection
• Lock connecting nipples of the cooling water tubes into the corresponding quick connect couplings:
Return line red to quick connect coupling, red (coolant return) and
supply line blue to quick connect coupling, blue (coolant supply).