Design and function
MIG/MAG welding
099-005130-EW501
07.03.2013
29
5.10 MIG/MAG welding
5.10.1 Connection for workpiece lead
NOTE
Note the polarity of the welding current!
Some wire electrodes (e.g. self-shielding cored wire) are welded using negative polarity.
In this case, the welding current lead should be connected to the "-" welding current
socket, and the workpiece lead should be connected to the "+" welding current socket.
•
Observe the information from the electrode manufacturer!
Figure 5-6
Item Symbol
Description
0
1
Connection socket, "+" welding current
•
MIG/MAG cored wire welding:
Workpiece connection
2
"-" welding current connection socket
•
MIG/MAG welding:
Workpiece connection
3
Workpiece
•
Insert the plug on the workpiece lead into the "-" welding current connection socket and lock.