8 Parameter overview
8.1
Zone parameter
Zone parameter
Short description
Chapter
Lo
-
Alarm
Lower temperature limit value / under
-
temperature
7.4.1
Hi
-
Alarm
Upper temperature limit value / excess
temperature
7.4.1
dL/dH
-
Tolerance band
Permitted deviation of actual temperature
from setpoint
7.4.1
P
-
Band
Parameter of the PID
-
Controller
7.2.1
Tn
Reset time
Parameter of the PID
-
Controller
7.2.1
Tv Derivative time
Parameter of the PID
-
Controller
7.2.1
Classification
Activate / deactivate classification
7.2.1
Softstart
Gentle heating due to limitation of output
7.3.1
Compound heating
Common, slow heating of zones
7.3.2
Boost
-
Offset
Brief increase of the target temperature
7.5.1
Boost
-
Duration
Time of temperature rise at BOOST
7.5.1
Maximal output level
Output level limitation to maximum value
7.2.3
Output level
Output presetting in manual operation
7.2.2
Current reference val-
ue
Nominal current of the zone to be moni-
tored
7.4.4
Current tolerance
Tolerance of current monitoring
7.4.4
Standby temperature
Lowering the temperature to a new set
point
7.5.2
Average output level
The average output level (Read Only)
7.4.2
Classification of zone
Found classification (Read Only)
7.2.1
pro CONTROL BASIC Manual
page 35
8.2
System parameter
Display
System parameter
Short description
Chapter
Slowest channel
The slowest zone during heating is
stored here
7.3.2
HH
-
Alarm
Shut
-
off temperature: Maximum upper
temperature limit value for all zones
7.4.1
Max temperature
difference of the
compound
Maximum temperature deviation of the
compound heating
7.3.2
Fahrenheit display
Presentation of the display
7.1.2
Thermocouple type
Type of the connected thermocouples
7.1.3
ID Level
User level
7.1.1
ID Code
Password
7.1.1
Pin Code
The displayed value is required if the
password has been forgotten. In this
case contact the service.
7.1.1
Default parameter
Reset to factory settings
7.5.3
Software Version
Shows the current software version of
the power card
Temperature heat
sink
Shows the current temperature of the
heat sink of the power card inside the
case
Temperature
Thermo
-
Terminal
Shows the current temperature of the
thermocouple terminal on the power
card
Software Version
Shows the current software version of
the firmware
34