Typical gas / oil system with A/C.
A jumper wire between Rc and Rh is
provided. There is no need to install
a jumper.
Wiring diagram for a typical oil burner,
hydronic zone / Air handler with A/C.
Cut the Rc / Rh link on the UZC4
Panel for systems requiring isolation.
Single
Transformer
Gas/Oil Systems
1 or 2 Stage Heat
Two
Transformer
Oil/ Hydro
Systems
Figure 14. Single transformer Gas / A/C system.
Figure 16. Conventional Heat Pump System
Figure 15. Two transformer Oil or Hydronic / A/C system.
Dual Fuel
Heat Pump
with “O” Type
Reversing Valve
HVAC SYSTEM WIRING
Figure 17. Single stage heat pump and single stage furnace.
Note that a Conventional & Dual fuel heat pump could wire up more or less the
same. The difference is how staged heat operates. In a Conventional system,
the indoor fan & the compressor continues to run when stage up occurs. In a
Dual Fuel system, the indoor fan & the compressor shuts down when stage up
occurs. The UZC4 will perform these functions automatically. All you have to
do is set the dip switches to the correct settings. Select DF or CONV at dip
switch #2, Bank 1. Choose to activate 2nd stage heat by TIMER or by
OUTSIDE AIR TEMPERATURE. (Optional Sensor Required)
You can also
use Multi-stage thermostats in any or all Zones.
When the thermostat stage up
heat demand is satisfied, the UZC4 will stage down, unless DF/OAS has been
selected and the outdoor temperature is lower than the OAS changeover
setting. In that case the system will continue in FUEL mode, until all heating
demands are fully satisfied.
Your Heat Pump may be capable of making
these decisions without the aid of the UZC4, in which case you may elect
to wire your system as shown in figure 17.
UZC4
Oil / Wood Burner
Primary Control
or
Boiler Control
or
Zone Valve
or
Pump Control
Terminals
Y
C
R
Y
G
C
TYPICAL FAN
CENTER
TERMINAL
BLOCK
OUTDOOR
CONDENSING
UNIT
*W
W*
RC/RH
LINK
RC/RH
LINK
Cut Rc/Rh
Jumper
Cut Rc/Rh
Jumper
*
Note:
Your Air Handler may include a W terminal. That
means it may have it’s own isolation circuit. If you can
confirm this, simply connect the W1 terminal to the W
terminal on the air handler. Do not cut the Rc / Rh jumper.
Wire up your Oil Burner, Pump Control, or Hydronic Zone
valve to the isolation terminals or wires provided in the air
handler. (follow dashed lines)The fan is controlled via
time delay relay inside the air handler, or set the UZC4
“FAN “ Dip Switch to the “HYDRO” position.
T
T
Hi Efficiency Heat Pump with built-in Outside
Air Changeover Capability. The Heat Pump
makes the decision to run the Furnace. Note
that the UZC4 can still operate the furnace in
Emergency Mode!
GAS/OIL
Furnace
1or2 STAGE
Y
C
OUTDOOR
CONDENSING
UNIT
Y2
G
Y1
W2
C
R
W1
EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 FAX 732-446-5362 E-Mail- [email protected]
12
T
T
IS
OLATION TERMINALS
OR WIRES
W2
W1
RH
RC
Y2
O
Y1
G
RC/RH
LINK
RC/RH
LINK
B
E
H
V
A
C
-
S
Y
S
T
E
M
W2
W1
RH
RC
Y2
O
Y1
G
B
E
H
V
A
C
-
S
Y
S
T
E
M
UZC4
*
*
GAS OR OIL
FORCED AIR
FURNACE
BACKUP HEAT
HEAT PUMP
1 STAGE
Wout
O
Y
C
R
UZC4
W2
W1
RH
RC
Y2
O
Y1
G
RC/RH
LINK
RC/RH
LINK
B
E
H
V
A
C
-
S
Y
S
T
E
M
W
Y
G
C
R
Typical heat pump system wiring with
electric resistance backup heat. Wire
up the reversing valve to either O or B,
depending on your system type.
Applies to air cooled or geothermal /
ground source systems.
Conventional 4
Stage Heat Pump
with a “B” Type
Reversing Valve
AIR HANDLER
WITH 1 0R 2 STAGE
ELECTRIC RESISTANCE
BACKUP HEAT
HEAT PUMP
2 STAGE
X / W
B
Y
C
R
UZC4
W2
W1
RH
RC
Y2
O
Y1
G
RC/RH
LINK
RC/RH
LINK
B
E
H
V
A
C
-
S
Y
S
T
E
M
W
Y
G
C
R
*
W2
O
B
Y2
Y2
Diagram reflects a Heat Pump with a “B” type
Reversing Valve
NOT
a neutral or Common
terminal designated as “B”.