Activation Command
eWBM LoRa AT Command Manual for Consumer Products, Rev. 0.6, 02/2021
13 | 49
AT+APPEUI
⚫
The AppEUI is a global application ID in IEEE EUI64 address space (Provided by the Lora Network Supplier)
⚫
16 Hex digit (8 Byte) input and output.
Table 3 AT+APPEUI
Syntax
Operation
Remark
AT+APPEUI
R
Readout the current value of AppEUI
[Example]
AT+APPEUI
70b3d57ed0010e4f
<OK>
WF
Update AppEUI with the specified value and store it in secure storage (in
Flash memory)
[Format] : AT+APPEUI <AppEUI> <ENTER>
[Example]
AT+ APPEUI
70b3d57ed0010e4f
<OK>
AT+APPKEY
⚫
To read out the Application key (AppKey). The AppKey is an AES-128 root key specific to the end-device
(Provided by the Lora Network Supplier)
.
⚫
32 hex digit (16 Byte) input and output.
Table 4 AT+APPKEY
Syntax
Operation Remark
AT+APPKEY
R
[Example]
AT+APPKEY
de52ddd16146079649c89a0c1bd9eae5
<OK>
WF
Update Application Key (16 Byte) with the specified value (ABP only) and
store it in secure storage (in Flash memory)
.
[Format] : AT+APPKEY <AppKey> <ENTER>
[Example]
AT+APPKEY
de52ddd16146079649c89a0c1bd9eae5
<OK>
➢
Note )
AppKey : 32 hex digit (16Byte)