Workflow (Restore via Folder Scan)
1. Based on the parameters defined in XTAccess, this application scans specific folders
on external backup or archiving systems.
2. When a clip file has been written to the scanned folder, XTAccess creates a copy of
the clip on the server specified in the XTAccess parameters.
The restored clip receives a new UmID and LSM ID:
◦
Multicam automatically assigns a UmID to the restored clip.
◦
A start LSM ID is specified in XTAccess and incremented as defined for each new
clip that is restored in order to find an empty location on the server.
The restored clip contains the clip metadata.
3. The restored clip is moved from the scanned folder to one of the following subfolders
on the external archiving or backup system:
◦
\Restore.done\: folder where the files are moved to when they are successfully
restored.
◦
\Restore.error\: folder where files are moved to when they failed to restore.
5.7.4.
Important Rules
Gigabit networks including EVS servers need to abide by the following rules:
•
The hardware used on GbE networks with EVS servers need to support jumbo
frames.
•
Both GbE ports of an EVS server need to be defined on different sub-networks.
•
Teaming between the GbE1 and GbE2 ports is not possible.
•
This is not possible to implement failover through the GbE network.
•
The GbE port available on the MTPC board (PC LAN) is a 100Base-T port.
This is used for monitoring purposes (XNet Monitor) or for the communication with
other applications (LinX). This can be in the same sub-network as the GbE port.
HARDWARE TECHNICAL REFERENCE MANUAL XT3 Server 12.05
5. Hardware Installation and Cabling
77
Содержание XT-3
Страница 1: ...HARDWARE TECHNICAL REFERENCE MANUAL Version 12 05 November 2014 ...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 17: ...Right View Back View HARDWARE TECHNICAL REFERENCE MANUAL XT3 Server 12 05 3 Hardware Specifications 7 ...
Страница 19: ...Right view Top view HARDWARE TECHNICAL REFERENCE MANUAL XT3 Server 12 05 3 Hardware Specifications 9 ...
Страница 100: ...Connector Layouts 90 6 Boards Description EVS Broadcast Equipment SA Issue 12 05 C November 2014 ...
Страница 101: ...HARDWARE TECHNICAL REFERENCE MANUAL XT3 Server 12 05 6 Boards Description 91 ...
Страница 103: ...Connectors Layouts HARDWARE TECHNICAL REFERENCE MANUAL XT3 Server 12 05 6 Boards Description 93 ...
Страница 105: ...Connectors Layouts HARDWARE TECHNICAL REFERENCE MANUAL XT3 Server 12 05 6 Boards Description 95 ...
Страница 107: ...Connectors Layouts HARDWARE TECHNICAL REFERENCE MANUAL XT3 Server 12 05 6 Boards Description 97 ...
Страница 109: ...Connectors Layouts HARDWARE TECHNICAL REFERENCE MANUAL XT3 Server 12 05 6 Boards Description 99 ...
Страница 122: ...Illustration 112 6 Boards Description EVS Broadcast Equipment SA Issue 12 05 C November 2014 ...
Страница 125: ......