5.8.2.
GP Out Connections
Relay Isolated Outputs (GP Out 1, 2, 3, 4)
Pin-Out
The user can define the functions, types and settings associated to the GPI outs in the
following applications:
•
Setup menu of the Remote Panel
•
IP Director settings (GPI and Auxiliary Track tab)
Specifications
•
normally open contact (power off -> open)
•
maximum 1 A
•
maximum 50 Volts
•
typical life time: 100.000.000 switchings
TTL Outputs (GP Out 5, 6, 7, 8)
Pin-Out
HARDWARE TECHNICAL REFERENCE MANUAL XS Server 12.05
5. Hardware Installation and Cabling
75