2. Introduction to Neuron

Neuron is a Network Attached Processor designed for the broadcast industry. Neuron is an extremely
powerful and flexible platform designed with IT connectivity in mind. Unlike most available “hybrid”
solutions, which are mainly just Ethernet ports bolted onto an SDI centric processing unit, Neuron is a
processing device with high-speed Ethernet I/O (dual 100Gbps) and optional SDI I/O.

Neuron is a multi-channel Ethernet bridge, whose firmware can be updated over its lifespan to adapt the
functionality and I/O configuration or to keep pace with the latest standards.

The main video (and embedded audio) processing unit is based on a massive FPGA with 9 times the
horsepower of our most powerful Synapse card. This equates to 6 times more horsepower per rack unit
(RU) at a maximum of 50% of the electrical power usage of Synapse.

Please visit the EVS Broadcast Equipment SA website at www.evs.com to obtain the latest information
on our new products and updates.

Remote Control Capabilities

The remote control options and the method of connecting to a computer using Ethernet are explained in
the Neuron control manual.

EVS Cerebrum software will increase the system flexibility of one or more NFR2000 frames.

We strongly advise you to use a remote personal computer or laptop PC installed with the EVS Cortex
software, as this increases the ease of use and understanding of Neuron. This program can be
downloaded from our website (

https://mi-sftp.evs.com/

free of charge.

INSTALLATION AND SERVICE MANUAL

Neuron NFR2000 | 2. Introduction to Neuron |

3

Содержание Neuron NFR2000

Страница 1: ...Neuron NFR2000 Version 4 1 March 2022 INSTALLATION AND SERVICE MANUAL...

Страница 2: ......

Страница 3: ...mational purpose and use only and subject to change without notice This manual cancels and replaces any previous versions thereof Copyright Copyright 2003 2022 EVS Broadcast Equipment SA All rights re...

Страница 4: ......

Страница 5: ...EVER operate this product if any cover is removed NE JAMAIS utiliser ce produit si le couvercle est retir NEVER wet the inside of this product with any liquid Ne mouillez JAMAIS l int rieur de ce prod...

Страница 6: ...professional use as mentioned below Ce produit est conforme aux exigences des normes r latives la famille de produits d quipements de contr le d clairage de spectacle audio vid o et audiovisuel usage...

Страница 7: ...ation and maintenance of the NFR2000 is considered service action L installation et la r vision du NFR2000 sont consid r es comme des actions d entretien The equipment is intended for installation in...

Страница 8: ...assis of the unit For continued protection against electric shock a correctly wired and grounded earthed three pin power outlet must be used Do not use a ground lifting adapter and never cut the groun...

Страница 9: ...t Description 4 2 2 LED Indicators 6 3 Installation 7 3 1 Preparing the Product for Installation 7 3 2 Unpacking 7 3 3 Module layout 7 3 4 Processing Module Installation and Replacement 8 3 5 Power Su...

Страница 10: ...ICONOGRAPHY Note Tip Warning viii March 2022 Issue 4 1 G...

Страница 11: ...has been added next to the text to highlight information on new and updated features The changes in the NFR2000 manual are listed below Dimensions diagrams See section Nominal Dimensions on page 14 IN...

Страница 12: ......

Страница 13: ...ions de manipulation de dispositifs sensibles l lectricit statique Unpacking EVS has carefully inspected this product before shipment to ensure years of trouble free service Upon reception please make...

Страница 14: ...kaging available please use your own packaging as long as it meets the following criteria Is able to withstand the weight of the product Holds the product snugly within the packaging Leaves at least 5...

Страница 15: ...the horsepower of our most powerful Synapse card This equates to 6 times more horsepower per rack unit RU at a maximum of 50 of the electrical power usage of Synapse Please visit the EVS Broadcast Eq...

Страница 16: ...essing modules from the back for broadcast versions and from the front for datacenter versions Redundant power supplies from the front for broadcast versions and from the back for datacenter versions...

Страница 17: ...Broadcast Version In the Broadcast version the power supplies and the I O connectors are on the back Front View Rear View INSTALLATION AND SERVICE MANUAL Neuron NFR2000 2 Introduction to Neuron 5...

Страница 18: ...Green constant Power present controlled no errors Green blinking Power present not controlled no errors Red constant No power present or AC DC converter defect controlled internal communication error...

Страница 19: ...act your EVS dealer if parts are missing or damaged or when products on the packing list are missing 3 2 Unpacking The Neuron frame must be unpacked and installed in an anti static environment Make su...

Страница 20: ...d firmly into the frame If a module slot remains empty the empty slot should be fitted with a blind panel 3 5 Power Supply Installation and Replacement Installing or Replacing the Power Supply in an N...

Страница 21: ...e power supplies When fans are reported as defective by Cortex or Cerebrum the PSU will have to be replaced If service has to be performed on the frame please ensure that the power supplies are switch...

Страница 22: ...e puissance et doit toujours tre orient vers le haut Mounting of the equipment in the rack should be such that a hazardous condition is not created due to uneven mechanical loading Electrical Connecti...

Страница 23: ...ight 44 mm 1 73 1RU Width 483 mm 19 Depth including power supply excluding processing module 605 mm 23 82 Depth including power supply and processing module 615 mm 24 21 Weight Weight without modules...

Страница 24: ...W Fuse 250V 8 A fast 2x not serviceable Max power per slot 200W Power factor full load 0 95 Each PSU is fused internally not customer serviceable Cooling Fans 4 fans in each PSU Required air volume fo...

Страница 25: ...UT is 1 meter Frames are placed one meter from the ground in a 19 rack of 47 RU All unused space is closed with blind panels NFR2000 Broadcast version fully loaded 80 dB A preliminary NFR2000 Datacent...

Страница 26: ...5 Nominal Dimensions The following diagrams show the nominal dimensions of the Neuron NFR2000 frame in mm Top 14 March 2022 Issue 4 1 G...

Страница 27: ...Side Back INSTALLATION AND SERVICE MANUAL Neuron NFR2000 5 Nominal Dimensions 15...