Copyright©2015 EVR Electronics.
All right reserved. Print only for private use.
www.gsmcontrol.biz
10
4.2 Command U (Users) - Programming telephone numbers Users
You can program the device up to 5 phone numbers of mobile users; you must program at least the number of cell
phones User 1. They will have a dual function:
Activate / Deactivate Temperature Comfort
The programmed numbers will be able to activate / deactivate the maintenance of room temperature to the set tem-
perature as Comfort. The CX36 reads the caller ID (without going to the line) and if present in memory "switch" func-
tion comfort (the active if it was off and vice versa).
If activated (Comfort ON), the device makes a call lasting some ring towards the user (who will not respond) to com-
municate the execution of the command. All this at no cost by both the mobile user that the SIM card in CX36.
When disabled (Comfort OFF) the device does not send ringback user. It is assumed that this step is performed
locally to exclude the thermostat GSM and pass control to the original thermostat or before leaving the house.
Feedback is entrusted to the green LED RUN.
Receiving SMS
Users will receive SMS messages stored sent voluntarily by the CX36. In particular, the User will receive 1 SMS
credit and residual maturity SIM if the Echo function is enabled; Users 1 through 5 will receive an SMS alert if the
temperature drops below the alarm threshold.
Example:
393939002525*
Text SMS
Description
0000
Password of the device
U
ID command
1
of the ID number to be programmed (number from 1 to 5)
+393939002525
Mobile number to program full of international identification
*
Symbol End of message
If the program is successful, the device replies with the following SMS:
Setup command OK User 1 programmed: +393939002525
Otherwise, the device will respond with the following text message:
Programming User Failed
Notes:
- You can program from 1 to 5 mobile numbers.
- You must program at least one cell phone number user.
- To delete, for example, the mobile phone number in the third position, send the following SMS: 0000U3 *
- To know the numbers stored as Members send the command U?:
0000U?
- The maximum length of each number is 16 digits.
- Always insert the country code before the number,
+39
for Italy.
- Carefully read the SMS response verifying that it is the memory location that the mobile phone number are correct.