EVOVX EVOAQ Скачать руководство пользователя страница 2

Setting your Ventilation Requirement  

Adjust the set ventilation with the Ventilation Rate Adjust        button. The setting will cycle 
through the different options below.

High ventilation

 - Fan will operate at high speeds across a wider range of 

temperature to actively work on Air Quality and condensation.

Medium ventilation

 - 

Fan will operate optimal airflows 

(default).

Low ventilation 

Fan will provide lower airflows while maintaining air quality.

Auto ventilation - 

Controller selects Low, Medium or High Ventilation 

depending on the difference between the room temperature and your 
comfort set temperature.

 

Low ventilation 

is suitable for low occupancy numbers in the house and when total 

ventilation requirements may be substituted with opening windows and doors 
(summertime).

Medium Ventilation

 (default) provides the ideal ventilation requirements for an 

average well-insulated home.

High Ventilation

 is suitable when there is a higher occupancy in the home or signs of 

poor air quality due to increased moisture levels in the house (condensation).

Auto mode

 maintains the requirements of the three rates based on temperature in the 

home. As well as providing the correct levels of ventilation, the system also tries to 
normalise the indoor air temperature to the target comfort level set by the user.

• 

• 

• 

Frequently Asked Questions

Which ventilation rate should I choose?

I turned the controller off. Why does the system keep running?

When turning the controller o

ff the fan enters a shutdown cycle which may take up to a 

minute to turn off fully.

• 

Wiring Diagrams

Fixed Wires

Com Volts -DC

12-24 Volts +DC

12 Volt AUX

Mode Output 

Aux Air Source

NC

NC

7

6

5

4

3

2

1

4a

Controller (back)

4b

Page 2

V1.1:20181005