This pump is built up for pumping water, free from explosive substances,solid
particles and fibers, with a density of 1kg/dmc and a kinematic viscosity of 1mm²
/ s and chemically non-aggressive liquids.
Assembly
1.
Inlet conenction
2.
Drain hole
3.
Stainles steel housing
4.
Plug cord
5.
ON/OFF switch
6.
Handle
7.
Outlet connection
WARNING! In case of any abnormal noise, immediately turn off the tool and
contact an authorized service facility for repairs
WARNING! If there is a suction pipe, it may take several minutes after start the
pump until water is delivered. This period depends on the length and diameter of
suction pipe.
Checking of the pump before installation
The pomp must be installed on a concrete foundation for enhanced stability and long
service
Install closing valve closer to the pump for an easy intervention in the case of testing and
repair
Site of installation
Before immersing the pump in the pit or tank, ensure that
the place is free from sand and solid sediment. In case
there is sediments, clean thoroughly the place.
Pump is working in horizontally position.
Keep the sorb above the bottom of pit as to avoid suction of
any deposit form after installation.
It is very important to ensure that water level never falls
below the body of pump.
DANGER OF FROST! Completely empty
the pump
through drain hole (2) when remains inactive at
temperature of less than 0ºC, to avoid damaging it.
Piping
The hydraulic connection could be made with iron or plastic parts, either rigid or flexible
Is recommended to use pipes with an internal diameter at least equal to that of delivery pipe,
as to avoid fall in performance and clogging
The size of pit must be calculated in relation to the estimated inflow and to the flow rate of
pump, to avoid an excessive number of starts for motor.
Fix the pipes as not to damage the pump body by weight
Make sure that the maximum suction depth does not exceed the level specified in the
technical data of the product.
On the suction pipe will be installed mandatory a check valve in the end placed in the well
to avoid intrusion of foreign particles
On the outlet pipe will be installed mandatory a non-return valve and a tap, in this order