24
WT.050.580.001.DE.IM.0714
Installation
Sensor measuring modules for MFC
4.
4.8.1
lAP download description
1
Connection:
•
Switch off the MFC mains voltage.
•
Connect the PC to the MFC using the interface cable
W3T164565
or
Set up the connection cable as described below:
Connection: RS232
Terminal MFC
9-pin D-Sub (PC/Laptop)
TxD13 ------------------------------>Pin 2 RxD
RxD14 ------------------------------>Pin 3 TxD
GND15------------------------------>Pin 5 GND
•
Switch on the MFC mains voltage.
•
Switch the MFC into download mode.
The menu for this mode is located in Input/Output under
interface.
•
Set RS232 to IAP download.
See Instruction Manual „MFC”.
2
Load program Update.exe
and press START.
3
Load wtf file to MFC
Load file "z.B. MFCV0100.wtf"
(Version 01.00 of MFC).