background image

4

 IMPORTANT INFORMATION AND HEALTH & SAFETY

When using electrical appliances, basic precautions should always be followed to reduce 
the risk of fire, electric shock, and injury to persons, including the following:

•  Read all of the instructions carefully before using the appliance, only use this appliance 

as described in this manual. Any other use not recommended by the manufacturer may 

Any other use not recommended by the manufacturer may 

cause injury to persons, or damage to the appliance.

cause injury to persons, or damage to the appliance.

•  Remove all packaging and dispose of it at an appropriate recycling facility.
• 

•  When transporting or storing the appliance and power lead, keep in a dry place, away 

When transporting or storing the appliance and power lead, keep in a dry place, away 
from excessive vibration and store so as to avoid damage.

from excessive vibration and store so as to avoid damage.

•  This fireplace is hot when in use. To avoid burns, do not let bare skin touch hot 

surfaces. The trim around the heater outlet becomes hot during heater operation. 
DANGER: High temperatures may be generated under certain abnormal conditions.

•  Do not install this appliance immediately in front of a fixed socket outlet.
•  Do not install this appliance in the immediate surroundings of a bath, shower, 

swimming pool or any other area where the appliance could come into contact with 
water or humidity, e.g. a bathroom.

• 

•  Do not use in areas where gasoline, paint, or any flammable liquids are used or stored. 

Do not use in areas where gasoline, paint, or any flammable liquids are used or stored. 

•  This appliance is only suitable for indoor use, do not use outdoors.
•  Do not cover the appliance, or let the air inlet/outlet to be obstructed in any way as it 

may overheat.

•  Keep the power lead away from hot surfaces and the heater outlet. Do not route the 

power lead in front of the appliance, or under any carpets or rugs.

•  A maintenance hatch must be installed into the surrounding installation to allow future 

access.

•  Always use a certified electrician should new circuits or outlets be required. And 

always use properly grounded, fused and polarised outlets.

•  Where the power lead passes through any masonry wall, stone surround etc. ensure 

that suitable rubber bushes are fitted at any possible wear points.

•  If the power lead is damaged do not use the appliance until it has been replaced.
•  Do not use any external switching device, timers, or extension leads. Do not connect 

the appliance to a circuit that is frequently switched on and off by the utility.

• 

•  In the event of a malfunction, switch off the appliance, and disconnect it from the 

In the event of a malfunction, switch off the appliance, and disconnect it from the 
mains power supply. Have the appliance inspected by a certified electrician before 

mains power supply. Have the appliance inspected by a certified electrician before 
reusing.

reusing.

•  Do not use the appliance if it is damaged. In the event of any damage to the appliance, 

please contact the retailer from whom the appliance was purchased.

•  Any repairs must only be performed by a certified electrician. 
•  Extreme caution is necessary when any heater is used by, located near children or 

people of reduced mobility, and whenever the unit is left operating and unattended.

•  Young children should be supervised to ensure that they do not play with the appliance.
• 

•  Disconnect from the power supply before performing any cleaning, maintenance or 

Disconnect from the power supply before performing any cleaning, maintenance or 
relocation of the unit. Do not use steam cleaners, or aerosols near the appliance.

relocation of the unit. Do not use steam cleaners, or aerosols near the appliance.

•  Do not burn wood or anything else in this appliance.
•  Do not strike the glass.
•  Do not drill or screw any new holes into the appliance.

EVONIC - 104 INSTRUCTION MANUAL TEMPLATE ISS. 1

EVONIC - 104 INSTRUCTION MANUAL TEMPLATE ISS. 1

DS ISS. 12

DS ISS. 12

Содержание LINDSTROM DS

Страница 1: ...e E Smart Evoflame E Smart INSTRUCTION MANUAL INSTRUCTION MANUAL Stora DS Stora DS Lindstrom DS Lindstrom DS English English EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL...

Страница 2: ...Evoflame E Smart 5 Installation 6 Model Dimensions 7 Requirements and Checks 8 Installation 9 Log Layouts 11 Installing Removing the Front Glass 13 Troubleshooting 14 Warranty Registration 16 EVONIC...

Страница 3: ...ction of Hazardous Substances References to the relevant designated standards used References to the relevant designated standards used EN 55014 1 2006 A1 2009 A2 2011 Electromagnetic Compatibility EN...

Страница 4: ...f the appliance or under any carpets or rugs A maintenance hatch must be installed into the surrounding installation to allow future access Always use a certified electrician should new circuits or ou...

Страница 5: ...ion E Series Instruction Manual Manual Woodland Woodland or Silver Birch or Silver Birch Lindstrom DS Lindstrom DS 4 x large 4 x large 4 x Clear 4 x Clear 4 x Amber 4 x Amber 5 x 5 x 1 x 1 x 1 x 1 x 1...

Страница 6: ...6 INSTALLATION INSTALLATION EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 DS ISS 12 DS ISS 12...

Страница 7: ...gs Model Width Height Depth Overall unit A A Overall unit B B Openings C C Overall unit D D Lindstrom DS 1056mm 558mm 355mm 530mm Stora DS 864mm 1208mm 1002mm 535mm EVONIC 104 INSTRUCTION MANUAL TEMPL...

Страница 8: ...ives to seal in the appliance and do not apply wet plaster directly to the appliance INSTALLATION REQUIREMENTS INSTALLATION CHECKS BEFORE INSTALLATION We recommend turning on the appliance before inst...

Страница 9: ...the installation 2 Determine the finished height and position that you want the appliance to be located Build your base support taking into consideration the 50mm ventilation gap under the appliance...

Страница 10: ...ine up with the plaster kits on the edge of the appliance 4 Your installation is now complete and you can set up your logs EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TE...

Страница 11: ...11 LOG LAYOUTS LOG LAYOUTS EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 DS ISS 12 DS ISS 12...

Страница 12: ...ermiculite lay this on the fuel bed first then continue with laying out your logs The following images show an example of how you could lay them out 4 x Small Woodland Silver Birch Stora 4 x Large Woo...

Страница 13: ...iner panel 2 Apply the Suction Lifter to the glass and place the bottom edge in first then angle the top edge into the appliance Then replace the top retainer panel EVONIC 104 INSTRUCTION MANUAL TEMPL...

Страница 14: ...14 TROUBLESHOOTING TROUBLESHOOTING EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 EVONIC 104 INSTRUCTION MANUAL TEMPLATE ISS 1 DS ISS 12 DS ISS 12...

Страница 15: ...aintenance series Please note this video shows an old method of removing the front glass panel Refer to page 25 for the new method E Smart Only E Smart LED Replacement Scan the QR code to be taken to...

Страница 16: ...o normal wear and tear or parts that require replacement in connection with normal maintenance are not covered within the extended warranty These items are covered for the first 12 months To make a wa...

Страница 17: ...ccurring during the warranty period years 2 5 CK Fires Ltd will send the appropriate component or goods necessary to rectify the fault free of charge Nothing in the Extended Warranty shall make CK Fir...

Отзывы: