6
INSTRUCTION MANUAL ISS. 3
INSTRUCTION MANUAL ISS. 3
Review and consider all the following conditions before installation:
Ensure installation does not allow the electric fireplace to be in direct contact with building vapour barrier
or insulation and meets all local building code. A 15 Amp, 120 Volt circuit is required. A dedicated circuit is
preferred but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit
breaker trips or fuse blows on a regular basis when the heater is operating. Additional appliances on the
same circuit may exceed the current rating of the circuit breaker.
Ensure the power cord is not installed so that it is pinched or against
a sharp edge and ensure that the power cord is stored or secured to
avoid tripping or snagging to reduce the risk of fire, electric shock
or injury to persons. Construction and electrical outlet wiring must
comply with local building codes and other applicable regulations to
reduce the risk of fire, electric shock and injury to persons.
WARNING: To reduce the risk of fire, do not store or use gasoline or other flammable vapours or liquids in
the vicinity of the heater.
1. Select a location that is not susceptible to moisture and is away from drapes, furniture and high traffic.
2. For ease of electrical hook up you may wish to locate the fireplace near an existing outlet (for plug-in
convenience).
3. Remove electric fireplace, front glass and hardware from the box and remove all packaging materials
before installation.
4. Store the fireplace in a safe, dry and dust free location until you are ready to install the fireplace.
Grounding Instructions:
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least
resistance for electric current to reduce the risk of electric shock.
This product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The
plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with
all local codes and ordinances. DANGER: Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to
whether the product is properly grounded. Do not modify the plug provided with the product – if it will not
fit the outlet, have a proper outlet installed by a qualified electrician. This product is for use on a nominal
120-volt circuit and has a grounding plug that looks like the plug in Figure 1. Make sure that the product is
connected to an outlet having the same configuration as the plug.
WARNING: Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock
or injury to persons, always use a licensed electrician. PLEASE NOTE: This appliance cannot be wired into a
wall and must use the provided cord and a wall outlet.
INSTALLATION REQUIREMENTS
Содержание Halo Kiruna
Страница 5: ...5 INSTRUCTION MANUAL ISS 3 INSTRUCTION MANUAL ISS 3 INSTALLATION INSTALLATION...
Страница 10: ...10 INSTRUCTION MANUAL ISS 3 INSTRUCTION MANUAL ISS 3 INSTALLATION GUIDE...
Страница 11: ...11 INSTRUCTION MANUAL ISS 3 INSTRUCTION MANUAL ISS 3...
Страница 14: ...14 INSTRUCTION MANUAL ISS 3 INSTRUCTION MANUAL ISS 3 LOG LAYOUTS LOG LAYOUTS...
Страница 33: ...33 INSTRUCTION MANUAL ISS 3 INSTRUCTION MANUAL ISS 3 PRODUCT PRODUCT SPECIFICATION SPECIFICATION...
Страница 43: ...43 INSTRUCTION MANUAL ISS 3 INSTRUCTION MANUAL ISS 3 TROUBLESHOOTING TROUBLESHOOTING...
Страница 45: ...45 INSTRUCTION MANUAL ISS 3 INSTRUCTION MANUAL ISS 3 Problem Possible Cause Solution...
Страница 46: ...46 INSTRUCTION MANUAL ISS 3 INSTRUCTION MANUAL ISS 3 Problem Possible Cause Solution...
Страница 47: ...47 INSTRUCTION MANUAL ISS 3 INSTRUCTION MANUAL ISS 3 Problem Possible Cause Solution 2 50mm...
Страница 48: ...48 INSTRUCTION MANUAL ISS 3 INSTRUCTION MANUAL ISS 3 WARRANTY WARRANTY...