INSTALLATION
First attach the electrical lead to the power
inlet on the back lower right, and plug into
the mains power.
Using the Cast Frame fixing kit, drill and fit
the x 2 wall plugs and x 2 screw eyes to the
inside of the wall opening.
Then using the cable, form a loop by
threading it through one of the holes on
the front of the appliance, then through
the eye screws, and back through another
hole on the appliance. You can use the
most conveniently positioned hole on the
appliance for your installation.
Now move the appliance into the opening,
pulling the solid end of the cable against the
appliance.
Feed the barrel clamp onto the open end of
the cable, and whilst maintaining tension
screw it tight.
Cut the cable approximately 50mm away from
the barrel clamp.
STRELLAR INFILL PLATE
STRELLAR & OBERON INSTALLATION
Our Strellar model comes with an infill
plate and 2x screws, if you have an Oberon
model you can skip to the section below and
continue with the installation.
To fit the Infill plate, screw in the two screws
to either side of the plate as shown. This
lines up with the two screw holes on the front
of the appliance.
You can now continue the installation in the
below section.
All our inset models are designed to be fitted into a standard 16” wide x 22” high opening.
Before starting the installation check the dimensions of both the appliance and your
opening to ensure that they align well.
Please note, if you are installing into an existing chimney breast it is imperative that the
flue is adequately blocked off.