Evolve Customer Support available at 856/552-4000, 888/827-2500, from 8:30 Eastern through 6 Eastern time, or fax at 856/552-4001.
Installation Manual – October 2000
Note
: Any alterations to listed components will void the manufacturer's warranty. The manufacturer will
not be responsible for any damage or bodily harm caused by alterations in accordance with national or
local electrical codes and manufacturer's specifications.
In accordance with the manufacturer's policy of continual product improvement, the product presented in
this document is subject to change without notice or obligation.
10
P
anels
Panels
Installation Instructions
End-of-Run Post Kit – Wall Mount Application
(EVPER)
Parts List
:
1 Slotted post with levelling glide
1 Single clamp
1 End trim kit
A Wall Mount is the same as an End-of-Run Post Kit. It is used to attach a
panel run to a fixed wall.
1. Select the panel that starts at the fixed wall.
2. Remove the panel top cap.
3.
Partially attach an Inline Connector to the end of the panel
furthest from the wall
by engaging the down-hook at the bottom of the
panel (above the raceway channel) over the up-hook on the slotted post.
4.
Attach the End-of-Run Post Kit to the end of the panel that will be
against the wall.
(See END-OF-RUN POST KIT opposite.)
5.
Level the panel
(consider the height of the rest of the run of panels)
6.
Locate the prepared panel at the desired position on the wall
and
mark the location.
7.
Remove trim kit from the slotted post
attached to the panel.
8. Drill 1/4" holes through the trim kit at 18" intervals.
9. Place trim kit on wall at marked location and mark holes.
10. Drill holes in wall.
11.
Attach trim kit to wall
. (Evolve does not supply mounting hardware)
12. Reattach the panel top cap.
13. Slide the panel onto the trim kit/Wall Mount.
1
2
3
6
5
4
7
8
9
10
11
12
13