![evoheat EVO COMMAND 140 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/evoheat/evo-command-140/evo-command-140_manual_2446565012.webp)
10
4.Installation
4.1 Transit
When the heat pump is transported please
keep the unit stand up. The unit cannot be
laid down, otherwise the inner parts of the
device may be damaged.
When the unit need to be hung up during
installation, a 8 metres cable is needed, and
there must be soft material between the cable
and the unit to prevent damage to the heat
pump cabinet. (See picture 1)
Or please use forklift, since there is wood
chassis as package.
WARNING
DO NOT touch the heat exchanger of the heat
pump with fingers or other objects
4.2 Installation occasions
The unit can be installed on any place outdoor which can carry heavy machine
such as terrace, housetop, ground and so on.
The location must have good ventilation.
The place is free from heat radiation and other fire flame.
A pall is needed in winter to protect the heat pump from snow.(See picture 2).
There must be not obstacles near the air inlet and outlet of the heat pump.
There must be water channel around the heat pump to drain the condensing
water .
A place which is free from strong air blowing.
There must be enough space around the unit for maintenance.
4.3 Installation method
The heat pump can be installed onto the concrete basement by expansion screws,
or onto a steel frame with rubber feet which can be placed on the ground or
housetop.
Make sure that the unit is placed horizontally.
4.4 Water loop connection
Please pay attention to below matters when the water pipe is connected:
Try to reduce the resistance to the water from the piping.
protector
hoist rope
handling hole
angle
40°
60°