9. Warranty 

 

Please refer to the EvoHeat website for warranty details 

 

Australia

www.evoheat.com.au

 

 

South East Asia: 

www.evoheat.com.sg

 

 

 

1.

 

Warranty terms are from date of purchase. 

2.

 

This warranty excludes any defect or injury caused by or resulting from misuse, abuse, neglect, accidental 

damage, improper voltage, vermin infestation, incompetent installation, any fault not attributable to faulty 

manufacture or parts, any modifications which affect the reliability or performance of the unit. 

3.

 

This warranty does not cover the following: 

a.

 

Natural Disasters (hail, lightening, flood, fire etc.) 

b.

 

Rust or damage to paintwork caused by a corrosive atmosphere 

c.

 

When serviced by an unauthorized person without the permission of Evo Industries 

d.

 

When a unit is installed by an unqualified person 

e.

 

Where a unit is incorrectly installed 

f.

 

When failure occurs due to improper or faulty installation 

g.

 

Failure due to improper maintenance (refer Operating Instructions) 

h.

 

‘No Fault Found’ service calls where the perceived problem is explained within the 

i.

 

Costs associated with delivery, handling, freighting, or damage to the product in transit. 

 

4.

 

If warranty service is required you should: 

a.

 

contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site 

b.

 

provide a copy of your receipt as proof of purchase 

c.

 

have completed the online warranty registration or provide a completed warranty card. 

 

5.

 

Onsite technical service is available within the normal operating area of your Evo Industries authorized Service 

Centre. Service outside this area will incur a traveling fee. 

6.

 

Unless otherwise specified to the purchaser, the benefits conferred by this express warranty and additional to 

all other conditions, warranties, rights and remedies expressed or implied by the Trade Practices Act 1974 and 

similar consumer protection provisions contained in legislation of the States and Territories and all other 

obligations and liabilities on the part of the manufacturer or supplier and nothing contained herein shall 

restrict or modify such rights, remedies, obligations or  liabilities. 

Warranty Registration 

EvoHeat highly recommend customers to complete their warranty details online to 

ensure efficient warranty claim processing.  

To register your warranty, scan our QR Code or head to our website and fill in the 

Warranty Registration Form: 

https://evoheat.com.au/warranty-registration/ 

 

 

Содержание CS-i Series

Страница 1: ......

Страница 2: ...Start up Shut Down ___________________________________________________________________ 9 5 2 2 Switching Modes Setting the Target Temperature ___________________________________________ 9 5 2 3 Clock...

Страница 3: ...130 Heat output at 27 C air 26 C water kW 65 130 Heat output at 15 C air 26 C water kW 50 100 Cooling output at 55 C air 35 C water kW 15 54 Cooling output at 45 C air 26 C water kW 30 73 C O P AT 27...

Страница 4: ...oHeat CS i Commercial Inverter Series Heat Pump 2 Unit Dimensions Evo CS i 65 unit mm Evo CS i 130 A L B W C H Water inlet outlet CS i 65 1750mm 830mm 1750mm 50 CS i 130 2260mm 1160mm 2127mm 100mm fla...

Страница 5: ...oad protection system After a previous stoppage the unit will not start for at least 3 minutes For unit cleaning or maintenance switch off and disconnect the power of the unit Do not install the unit...

Страница 6: ...on the front panel of the unit The gauge should be showing a pressure of approx 10 20 on the outside red band any less than this figure means there may be a leak in the refrigerant system and you shou...

Страница 7: ...nstalled a maximum of 5m below the water level of the pool spa If further than 5M please discuss with your EvoHeat specialist for the best advice Make sure the heat pump is not located where large amo...

Страница 8: ...in the air condenses on the fins of the evaporator During times of high humidity the condensate may be several litres per hour This may give the impression that the heater is leaking however this is a...

Страница 9: ...he unit to heat the pool or spa the filter pump must be running to circulate water through the heat exchanger After installation is completed follow the steps below 1 Turn on your filter pump Check fo...

Страница 10: ...perature interface 7 Temperature Curve Click to view the temperature and power curve 8 Water Inlet Temperature Press to enter mode setting and the target temperature interface 9 LOCK Click to lock the...

Страница 11: ...nction 1 Timing Start Button Start Green End Grey Click this button to start or end the timing start setting function 2 Timing On Setting Click to set the start time of the timer 3 Timing End Button O...

Страница 12: ...check the failure record the main interface will display a static The failure record is in reverse order according to the time of occurrence Press the clean key to delete all fault records 5 2 6 Colou...

Страница 13: ...eaners to ensure proper water flow Is the current pool spa water temperature higher than the set temperature on the controller If so the unit will not operate until the pool spa water temperature fall...

Страница 14: ...If the water has chlorine it is a water leak and you need to contact EvoHeat tech support on 1300 859 933 Or Turn the heater off and run the water pump continuously for a period of 2 4 hours If the wa...

Страница 15: ...rcuit Flow Switch Prot E03 No water little water in water system Check the pipe water flow and water pump Waterway Anti freezing Prot E05 Water temp or ambient temp is too low Inlet and outlet temp to...

Страница 16: ...eck the input voltage measurement Inv Sampling Volt F11 The input voltage sampling fault Check and adjust the current measurement Comm Err DSP PFC F12 DSP and PFC connect fault Check the communication...

Страница 17: ...101 123A 2 x 35mm2 35mm2 160A 30mA less than 0 1 sec 123 148A 2 x 50mm2 50mm2 225A 30mA less than 0 1 sec 148 186A 2 x 70mm2 70mm2 250A 30mA less than 0 1 sec 186 224A 2 x 95mm2 95mm2 280A 30mA less t...

Страница 18: ...17 EvoHeat CS i Commercial Inverter Series Heat Pump 7 3 Wiring Diagrams 7 3 1 CS i 65...

Страница 19: ...18 EvoHeat CS i Commercial Inverter Series Heat Pump 7 3 2 CS i 130...

Страница 20: ...rature input 13 AI DI06 Water input temperature input 14 AI DI07 Water output temperature input 15 AI DI08 System fan coil temperature input 16 AI DI09 Ambient temperature input 17 AI DI10 Mode switch...

Страница 21: ...time 8 1 Energy Saving Tips If your pool water is allowed to cool significantly it may take several days to return to the desired swimming temperature For weekend use it is more economical to maintai...