EvoHeat CS-i Commercial Inverter Series Heat Pump 

No. 

Name 

Colour 

Function 

Timing silent off 

Used: Red 

Unused: Grey 

Click to use or unused timing off function 

Timing silent on 

Used: Green 

Unused: Grey 

Click to use or unused timing silent function 

Timing silent start time 

 

Click this button to set the timing silent start time 

Timing silent end time 

 

Click this button to set the timing silent end time 

 

The start and end time values me be within the range of 0:00 – 23:00; the value can be precise to the hour digit. 

Example: Click ‘ON’ to use timing silent. The unit will begin silent mode from 0:00 and end at 4:00. Click ‘OFF’ to turn 

off the timing silent manually, however the unit will turn off this setting once it reaches the end time. 

5.2.5 Fault History 

To view the fault records, press (4). 

If there is no failure, the main interface will display a static “

” 

When a fault occurs, the fault icon will flash. When this occurs, the failure 

interface will record the time, code and name of the fault. 

After troubleshooting, if you do not check the failure record, the main 
interface will display a static symbol: “

“ 

If you check the failure record, the main interface will display a static: “

” 

The failure record is in reverse order according to the time of occurrence. Press the clean key to delete all fault 

records. 

5.2.6 Colour Display Calibration 

Keep clicking quickly on the blank area at any interface until you hear a long beep. You will then enter the calibration 

interface. Click “+” to start calibration. When you hear the beep again, you will finish calibration and exit. 

Note: The wire controller can display the temperature unit as ‘°F’ or ‘°C’ according to the model you bought. 

5.2.7 Temperature Curve 

Press the TEMP CURVE (7) button to view the 

temperature curve & average power curve. 

 

The temperature curve automatically updates every hour 

and will be stored for 60 days. 

If the unit is powered off after less than 1 hour of operation, the data in this period will not be saved. 

5.2.8 Boost Mode 

The CSi system is capable of operating in high output Boost mode to assist in 

reaching the desired target temperature faster.   

You can activate boost mode by simply pressing the “Boost” button in the 

display. 

When the target water temperature is reached, the system will automatically 

deactivate Boost mode and retrain to normal operation. 

Alternatively, Boost mode can be manually deactivated by simply pressing the 

“Boost” button again to turn it off. 

 

Содержание CS-i Series

Страница 1: ......

Страница 2: ...Start up Shut Down ___________________________________________________________________ 9 5 2 2 Switching Modes Setting the Target Temperature ___________________________________________ 9 5 2 3 Clock...

Страница 3: ...130 Heat output at 27 C air 26 C water kW 65 130 Heat output at 15 C air 26 C water kW 50 100 Cooling output at 55 C air 35 C water kW 15 54 Cooling output at 45 C air 26 C water kW 30 73 C O P AT 27...

Страница 4: ...oHeat CS i Commercial Inverter Series Heat Pump 2 Unit Dimensions Evo CS i 65 unit mm Evo CS i 130 A L B W C H Water inlet outlet CS i 65 1750mm 830mm 1750mm 50 CS i 130 2260mm 1160mm 2127mm 100mm fla...

Страница 5: ...oad protection system After a previous stoppage the unit will not start for at least 3 minutes For unit cleaning or maintenance switch off and disconnect the power of the unit Do not install the unit...

Страница 6: ...on the front panel of the unit The gauge should be showing a pressure of approx 10 20 on the outside red band any less than this figure means there may be a leak in the refrigerant system and you shou...

Страница 7: ...nstalled a maximum of 5m below the water level of the pool spa If further than 5M please discuss with your EvoHeat specialist for the best advice Make sure the heat pump is not located where large amo...

Страница 8: ...in the air condenses on the fins of the evaporator During times of high humidity the condensate may be several litres per hour This may give the impression that the heater is leaking however this is a...

Страница 9: ...he unit to heat the pool or spa the filter pump must be running to circulate water through the heat exchanger After installation is completed follow the steps below 1 Turn on your filter pump Check fo...

Страница 10: ...perature interface 7 Temperature Curve Click to view the temperature and power curve 8 Water Inlet Temperature Press to enter mode setting and the target temperature interface 9 LOCK Click to lock the...

Страница 11: ...nction 1 Timing Start Button Start Green End Grey Click this button to start or end the timing start setting function 2 Timing On Setting Click to set the start time of the timer 3 Timing End Button O...

Страница 12: ...check the failure record the main interface will display a static The failure record is in reverse order according to the time of occurrence Press the clean key to delete all fault records 5 2 6 Colou...

Страница 13: ...eaners to ensure proper water flow Is the current pool spa water temperature higher than the set temperature on the controller If so the unit will not operate until the pool spa water temperature fall...

Страница 14: ...If the water has chlorine it is a water leak and you need to contact EvoHeat tech support on 1300 859 933 Or Turn the heater off and run the water pump continuously for a period of 2 4 hours If the wa...

Страница 15: ...rcuit Flow Switch Prot E03 No water little water in water system Check the pipe water flow and water pump Waterway Anti freezing Prot E05 Water temp or ambient temp is too low Inlet and outlet temp to...

Страница 16: ...eck the input voltage measurement Inv Sampling Volt F11 The input voltage sampling fault Check and adjust the current measurement Comm Err DSP PFC F12 DSP and PFC connect fault Check the communication...

Страница 17: ...101 123A 2 x 35mm2 35mm2 160A 30mA less than 0 1 sec 123 148A 2 x 50mm2 50mm2 225A 30mA less than 0 1 sec 148 186A 2 x 70mm2 70mm2 250A 30mA less than 0 1 sec 186 224A 2 x 95mm2 95mm2 280A 30mA less t...

Страница 18: ...17 EvoHeat CS i Commercial Inverter Series Heat Pump 7 3 Wiring Diagrams 7 3 1 CS i 65...

Страница 19: ...18 EvoHeat CS i Commercial Inverter Series Heat Pump 7 3 2 CS i 130...

Страница 20: ...rature input 13 AI DI06 Water input temperature input 14 AI DI07 Water output temperature input 15 AI DI08 System fan coil temperature input 16 AI DI09 Ambient temperature input 17 AI DI10 Mode switch...

Страница 21: ...time 8 1 Energy Saving Tips If your pool water is allowed to cool significantly it may take several days to return to the desired swimming temperature For weekend use it is more economical to maintai...

Страница 22: ...y handling freighting or damage to the product in transit 4 If warranty service is required you should a contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site b prov...

Отзывы: