01-2018 5035 01
27
INITIAL START UP
When the appliance starts up for the first
time, a guided sequence will be displayed
with some preliminary settings (language,
appliance name, etc.).
After the choices have been made, the hy-
draulic circuit is filled up (installation).
When the appliance starts up, the mains
solenoid valve is opened automatically until
the hydraulic circuit is filled up.
Note: If there is a lack of water during
the installation cycle, the appliance will
stop and wait for the water.
If substantial water pockets form in the
hydraulic circuit, then the hydraulic cir-
cuit must be manually filled.
After the hydraulic circuit is filled, the appli
-
ance rotates the brewing unit to correctly
position it; the display shows the following
in sequence:
-The software version of the appliance and
the software version of the touchscreen.
-The heating cycle status of the boilers.
When the heating cycle has finished, the
beverages will be available.
FIRST SANITISATION
When the appliance has been installed, a
thorough food circuit disinfection needs to
be performed (brewing unit, mixers, bever-
age dispensing ducts, inner tank, milk tank,
etc.) to ensure that the dispensed products
are hygienic.
Do not under any circumstances use
jets of water when cleaning.
The sterilisation is performed using sterilis-
ing products.
Wash the mixers by adding a few drops of
sanitising solution and fully wash the cap-
puccino maker and the brewing unit.
Once the sterilisation has been performed,
rinse the mixers well to remove any residue
from the solution that has been used.
To supply water to the mixers, use the rinse
function from the "washes" menu.
Important!
This machine is equipped with an automat-
ic washing programme for the main func-
tional groups.
If the appliance is subject to idle periods
(weekends, etc.), even for periods of less
than two days, it is good practice to enable
the automatic washing functions (before
beginning to use the appliance).