If there are problems in operating, please refer to the checklist below. If the problem persists,
please contact the agent where this product is purchased.
Problems
Troubleshooting
Nothing appears on the
screen.
·
Please check that the power cord and line connection
between the camera and monitor are fixed properly.
·
Please check that you have properly connected VIDEO
cable to the camera VIDEO output jack.
The image on the screen
is dim.
·
Is lens stained with dirt? Clean your lens with soft,
clean cloth.
Set the monitor to proper condition.
485 Control Board Connection Port
(+)CONNECTION TERMINAL(TRX+)
(-)CONNECTION TERMINAL(TRX-)
RS-485 Control Port
485+
485-
Item
Initial value
Camera ID
1
BAUD RATE
9600
UART MODE
8-NONE-1
RET PKT
ENABLE
·
If the camera is exposed to too strong light, change
the camera position.
·
The image on the screen
is dark.
·
Adjust the contrast feature of the monitor.
·
If you have an intermediate device,
L=SURSHUO\
(Please check the impedance)
The camera is not working
properly, and the surface
of the camera is hot.
·
Please check that you have properly connected the
camera to an appropriate power source.
7KH'$<1,*+7PHQX
does not work.
·
3OHDVHFKHFNLI'$<1,*+7PHQXLVVHWWRµ$872¶
The SENS-UP function
does not work.
Color is not correct.
The MOTION DETECTION
function is not working.
Problems
Troubleshooting
RS-485
communication fails.
·
Please check the polarity between RS-485 Control Port
and RS-485 cable.
·
Please check if the initial value of the RS-485
Communication setup matches between camera and
OSD Controller or DVR.
·
We recommend that you make ground connection
between camera and controller for safe communication
control.
·
When RS-485 cable is not properly connected, A warning
Then please turn off the power and connect the cable again.
message
µ
ERROR RS-485 Connection. Please reconnect
and Reboot
¶
is displayed.
*
RS-485 Communication establishment initial value
9. Troubleshooting
9. Troubleshooting
·
3OHDVHFKHFNWKDW$*&RI(;32685(6(783PHQXLV
VHWWRµ2))¶
·
3OHDVHFKH877(5RI(;32685(6(783
PHQXLVVHWWRµ$)/.¶RUµ),;('¶
·
Please check if MOTION DETECTION function is
turned on.
·
Please check if MD LEVEL is too low.
·
Please check the setting of the MD area.
·
3OHDVHFKHFNWKHVHW,7(%$/6(783PHQX
The screen flickers
continually.
·
Please check that direction of camera turns toward
the Sun.