Short sheet-to-sheet connectors (B): When adjacent Auragami Light Sheets are mounted side-by-side with connection blocks aligned, the shorter 

sheet-to-sheet connection wires (B) should be used to interconnect multiple sheets. Their lengths are optimized so sheets align snugly. See Figure 1. 

When connecting Light Sheets that are already mounted to a fixed surface, the short connection wires (B) will need to be shaped as shown in Figure 

2 prior to pushing into connection blocks. Best practices include using two sheet-to-sheet connection wires for all adjacent Light Sheets in each Class 2 

circuit to minimize voltage drop. Dry-fit test for proper illumination prior to mounting Light Sheets to the mounting surface and again before the forward 

facing material is installed.

Long sheet-to-sheet connectors (C):

Use the long sheet-to-sheet connection wires (C) to bridge gaps and/or connect offset sheets as 

shown in Figure 3. 

Domed protective bumpers (D):

Rated for 400 lbs each, the domed protective bumpers (D) included with each Light Sheet have 

been engineered to bear the weight of translucent materials in horizontal applications and act 

as a safeguard in vertical applications so that the forward facing material does not harm the 

Light Sheet’s integrated connection blocks or LEDs. Evo-Lite recommends using eight bumpers 

per Light Sheet (approximately six per square foot), spacing them evenly to distribute the weight 

of the forward facing material (see Figure 4) and to add a level of protection in vertical applications 

when the forward facing material will be positioned near the Light Sheet (see Figure 5). A rigid, 

non deforming mounting surface/substrate must be used with any weight bearing applications to 

avoid damaging the Auragami Light Sheet.

Cable management clips (G) (included in the power input kit sold separately):

Route the connection wires so that the light from the LEDs is not blocked and hold the wires in this 

position using cable management clips with silicone adhesive backing (G) as shown in Figure 3. 

Once applied, let this adhesive backing cure for 10-30 minutes before routing wires through the 

clip. When possible, use a mechanical fastener to secure the clip. 

AURAGAMI

®

 DRY FITTING, CUTTING* AND FOLDING

 

Dry fit the sheets and connection wires before mounting the Light Sheets to the substrate. 

Always test function before installing the translucent (forward 

facing) material. 

To make a fold in an Auragami Light Sheet, bend the sheet along one of the dotted lines marked on the sheet, then crease along this line, then relax the 

fold into a 90° (or other desired) angle. 

Be careful about folding where an LED is attached to the sheet since LEDs can break if forced over an edge. Do not 

repeatedly fold and unfold along the same line as this will weaken the flexible PCB. Do not fold a Light Sheet back onto itself, however two separate Light 

Sheets can be attached back-to-back.

To make a cut in an Auragami Light Sheet, use shears, scissors, a utility knife and/or a precision/craft knife. Cut 

on horizontal, vertical and/or diagonal lines. Deviating from the lines could cut off power to one of more LEDs.

 

 

If a cut edge has the possibility of making contact with a conductive surface or another cut edge, cover the cut 

edge with RTV sealant or conformal coating.

 If one or more connection blocks exist on a cut/fold line, it is best 

to remove the connection block* to make a clean fold or cut. Using a pair of slip-joint pliers, grasp the connection 

block firmly (front side to back as illustrated at right) and rotate it either clockwise or counterclockwise while 

holding the Light Sheet in place. The connection block will unseat from the solder. Repeat for other connection 

blocks as needed and discard the removed block(s).

Figure 1

Figure 2

Figure 3

Figure 4

Figure 5

Integrated 3-pin

connection block

Translucent (Forward Facing) Material

Translucent

(Forward Facing) 

Material

Integrated 3-pin

connection block

B

B

C

B

C

D

D

G

* Not to Scale

B

C

D

G

SHORT SHEET-TO-SHEET CONNECTION WIRES

LONG SHEET-TO-SHEET CONNECTION WIRES

PROTECTIVE BUMPERS

CABLE MANAGEMENT CLIPS

USING AURAGAMI

®

 ACCESSORIES

53 mm (2.08”)

117 mm (4.60”)

9 mm

(0.35”)

12.8 mm (0.50”)

8.85 mm

(0.35”)

10 mm

(0.39”)

31 mm 

(1.22”)

*NEVER CUT OR ALTER LIGHT

SHEET(S) WHILE POWERED.

OR

DIAGONAL CUTTING ADVISORY

Auragami Tunable White must contain at least two 

contiguous diagonal rows of LEDs when cutting the 

sheet diagonally. Cutting a single diagonal strip of 

LEDs may result in certain LEDs malfunctioning. It 

is recommended to cut slightly outside the cutting 

line  when  cutting  diagonally.  Please  refer  to  the 

examples depicted to the right. 

Incorrect

Correct

Incorrect

Correct

Содержание Auragami AG1-24-TW

Страница 1: ...ons before beginning To reduce the risk of fire electric shock or injury to persons pay close attention to this manual and stay within its guidelines when using this product Save these instructions for future use READ AND FOLLOW THE PRODUCT HANDLING INSTALLATION INTEGRATION ADVISORY ON PAGE 4 DISCONNECT POWER AT THE SOURCE BEFORE CUTTING OR ALTERING THE LIGHT SHEET S IN ANY WAY DO NOT CONNECT LIGH...

Страница 2: ... to secure the clip AURAGAMI DRY FITTING CUTTING AND FOLDING Dry fit the sheets and connection wires before mounting the Light Sheets to the substrate Always test function before installing the translucent forward facing material To make a fold in an Auragami Light Sheet bend the sheet along one of the dotted lines marked on the sheet then crease along this line then relax the fold into a 90 or ot...

Страница 3: ...aking sure the two sections are not connected electrically see Figure 6 Figure 6 Use the power lead E to route power from the power supply to a single Light Sheet or a set of up to eight Light Sheets Use Wago connectors F in place of wire nuts for a secure connection of wires of the same polarity see figure 7 Do not exceed the 4 A maximum load capacity of a connection block in any configuration no...

Страница 4: ...unique challenges we hope by making you aware of the following handling and installation guidelines you are empowered with knowledge for a successful installation As always your Evo Lite Systems Integration Specialist or any of our staff are ready to assist you with any questions that arise during your installation FOLDING MINIMUM RADIUS There is no minimum bending radius for Auragami Light Sheets...

Отзывы: