background image

WWW.EVO-LITE.COM

   •   

[email protected]

   •   

1-888-887-2980

   •   ©2020 EVO-LITE, LLC  •  6240 W 54TH AVE., ARVADA, CO 80002  •  V2–3220

TEST BEFORE 

INSTALLING

Our production, packaging and shipping process is accompanied by a rigorous quality control procedure. 

All Auragami Light Sheets are subjected to a burn in period and are tested before packaging to ensure 

operation of the highest quality. Due to possible unforeseen issues with shipping and handling, we 

advise that all Light Sheets be inspected at time of delivery and dry-fit tested for proper illumination 

prior to mounting and again before the forward facing material is installed. 

FRAGILE 3-PIN 

CONNECTION 

BLOCKS

DISCONNECT POWER AT THE SOURCE BEFORE REMOVING ANY CONNECTION BLOCKS. 

The Light 

Sheet’s integrated 3-pin connection blocks are made of plastic which can be damaged if made to bear weight. 

Use domed protective bumpers (included) to bear the weight of any forward facing material in horizontal 

applications and to act as a safeguard to protect the Light Sheet in vertical applications.

DRILLING

DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE SHEET IN ANY WAY. 

Light Sheets have 

specific areas where holes can be made in the sheet. The smaller diameter circles on the Light Sheet 

(0.12” / 3 mm) indicate the maximum diameter of screw or other fastener’s shaft that can be used 

without causing damage to the Light Sheet’s power distribution grid. The larger diameter circle (0.24” / 6 

mm) is the maximum diameter of the screw head that can be used without causing damage. 

PRODUCT HANDLING, INSTALLATION & INTEGRATION ADVISORY

INSTALLATION 

TEMPERATURE 

Due to the characteristics of the 3M adhesive backing, installation environments and locations should 

be taken into consideration. Low temperatures can cause longer cure times for permanent adhesion. 

STORAGE

Store Auragami Light Sheets in a clean, dry area on a flat, horizontal surface. Do not open the anti-static 

envelope until ready to install. Ideal storage conditions: Temperature of 68° – 77° F, 50% humidity.

STORAGE

DO NOT CONNECT 

TO AC POWER

ANY DIRECT CONNECTION OF AURAGAMI LIGHT SHEETS TO AC CURRENT WILL DAMAGE THE LEDs. 

Be sure to use a UL Listed or UL Recognized Class 2, LPS or LVLE low voltage power supply that conforms 

to the voltage requirements of the Light Sheet. This information can be found on the Auragami Light 

Sheet and its packaging, as well as the power supply labeling.

Evo-Lite’s experience in providing backlighting solutions yields a unique perspective on the characteristics and underlying intuitive knowledge necessary to complete a 

successful installation of Auragami. Evo-Lite is committed to educating and supporting all our customers so every installation proceeds as smoothly as possible. Most 

installations offer their own unique challenges; we hope by making you aware of the following handling and installation guidelines you are empowered with knowledge 

for a successful installation. As always, your Evo-Lite Systems Integration Specialist or any of our staff are ready to assist you with any questions that arise during your 

installation.

FOLDING & 

MINIMUM RADIUS

There is no minimum bending radius for Auragami Light Sheets, however a single sheet may not be 

folded on itself because this could disrupt the flow of electricity through the folded sheet. Two separate 

IP65 sheets may be attached back-to-back since the 3M adhesive backing will act as non-conductive 

barrier. Light Sheets are not recommended for applications where a radius of less than 2” exists.

CUTTING

DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE SHEET IN ANY WAY.

  NEVER CUT 

AURAGAMI LIGHT SHEET WHILE POWERED. Field cutting of the Light Sheet does not void UL Listing. LEDs 

can lose input power if cut lines are not followed. Avoid cut edge contact with any conductive material(s), 

including other cut edges of Light Sheets. See also Wet Location Use below.

SOLDERING

DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE SHEET IN ANY WAY. 

Solder sheets or 

strips of Auragami together or solder power input(s) to Light Sheets. The Light Sheet’s copper pads are 

engineered to handle 4 A of load and polarity is noted by the + and - next to each copper pad. Use 20 

AWG stranded copper wire for up to 4 A of load and follow electronics soldering best practices. 

FASTENING

USE PAN HEAD, DOMED, OR ROUND HEAD FASTENERS, NOT TAPERED SCREWS. 

Never screw the 

fastener so much that it deforms the Light Sheet. Only penetrate the Light Sheet within the smallest 

of the two concentric circles marked on the sheet (see Drilling above for screw size limitations). For 

suspended applications, use mechanical fasteners with an appropriate spacing to avoid sagging.  

WET LOCATION 

USE

Auragami Light Sheets are rated IP65. This rating is total protection against dust ingress as well as water 

projected by a nozzle against the enclosure from any direction for a limited time and may be used in wet 

locations, but not where standing water can accumulate. Cut edges of IP65 can optionally be sealed from 

moisture with an RTV Silicone Sealant or conformal coating.

IP65

POWER, CONTROL 

& WIRING

For optimal power distribution and to minimize voltage drop, it is recommended that multi-strand, high 

strand count wiring be used for all low voltage DC connections. Wire gauge should be appropriate based 

upon system voltage and wire lengths to further minimize voltage drop.  Power supplies, drivers and 

controls should be installed in well ventilated enclosures and/or per manufacturers recommendations. 

It is the customer’s responsibility to ensure all components and installation practices meet or exceed 

local codes and requirements.

Auragami® is a patented product of Evo-Lite, LLC. For more information please visit 

www.evo-lite.com/patent

Содержание Auragami AG1-24-TW

Страница 1: ...ons before beginning To reduce the risk of fire electric shock or injury to persons pay close attention to this manual and stay within its guidelines when using this product Save these instructions for future use READ AND FOLLOW THE PRODUCT HANDLING INSTALLATION INTEGRATION ADVISORY ON PAGE 4 DISCONNECT POWER AT THE SOURCE BEFORE CUTTING OR ALTERING THE LIGHT SHEET S IN ANY WAY DO NOT CONNECT LIGH...

Страница 2: ... to secure the clip AURAGAMI DRY FITTING CUTTING AND FOLDING Dry fit the sheets and connection wires before mounting the Light Sheets to the substrate Always test function before installing the translucent forward facing material To make a fold in an Auragami Light Sheet bend the sheet along one of the dotted lines marked on the sheet then crease along this line then relax the fold into a 90 or ot...

Страница 3: ...aking sure the two sections are not connected electrically see Figure 6 Figure 6 Use the power lead E to route power from the power supply to a single Light Sheet or a set of up to eight Light Sheets Use Wago connectors F in place of wire nuts for a secure connection of wires of the same polarity see figure 7 Do not exceed the 4 A maximum load capacity of a connection block in any configuration no...

Страница 4: ...unique challenges we hope by making you aware of the following handling and installation guidelines you are empowered with knowledge for a successful installation As always your Evo Lite Systems Integration Specialist or any of our staff are ready to assist you with any questions that arise during your installation FOLDING MINIMUM RADIUS There is no minimum bending radius for Auragami Light Sheets...

Отзывы: