• ©2020 EVO-LITE, LLC • 6240 W 54TH AVE., ARVADA, CO 80002 • V2–3220
TEST BEFORE
INSTALLING
Our production, packaging and shipping process is accompanied by a rigorous quality control procedure.
All Auragami Light Sheets are subjected to a burn in period and are tested before packaging to ensure
operation of the highest quality. Due to possible unforeseen issues with shipping and handling, we
advise that all Light Sheets be inspected at time of delivery and dry-fit tested for proper illumination
prior to mounting and again before the forward facing material is installed.
FRAGILE 3-PIN
CONNECTION
BLOCKS
DISCONNECT POWER AT THE SOURCE BEFORE REMOVING ANY CONNECTION BLOCKS.
The Light
Sheet’s integrated 3-pin connection blocks are made of plastic which can be damaged if made to bear weight.
Use domed protective bumpers (included) to bear the weight of any forward facing material in horizontal
applications and to act as a safeguard to protect the Light Sheet in vertical applications.
DRILLING
DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE SHEET IN ANY WAY.
Light Sheets have
specific areas where holes can be made in the sheet. The smaller diameter circles on the Light Sheet
(0.12” / 3 mm) indicate the maximum diameter of screw or other fastener’s shaft that can be used
without causing damage to the Light Sheet’s power distribution grid. The larger diameter circle (0.24” / 6
mm) is the maximum diameter of the screw head that can be used without causing damage.
PRODUCT HANDLING, INSTALLATION & INTEGRATION ADVISORY
INSTALLATION
TEMPERATURE
Due to the characteristics of the 3M adhesive backing, installation environments and locations should
be taken into consideration. Low temperatures can cause longer cure times for permanent adhesion.
STORAGE
Store Auragami Light Sheets in a clean, dry area on a flat, horizontal surface. Do not open the anti-static
envelope until ready to install. Ideal storage conditions: Temperature of 68° – 77° F, 50% humidity.
STORAGE
DO NOT CONNECT
TO AC POWER
ANY DIRECT CONNECTION OF AURAGAMI LIGHT SHEETS TO AC CURRENT WILL DAMAGE THE LEDs.
Be sure to use a UL Listed or UL Recognized Class 2, LPS or LVLE low voltage power supply that conforms
to the voltage requirements of the Light Sheet. This information can be found on the Auragami Light
Sheet and its packaging, as well as the power supply labeling.
Evo-Lite’s experience in providing backlighting solutions yields a unique perspective on the characteristics and underlying intuitive knowledge necessary to complete a
successful installation of Auragami. Evo-Lite is committed to educating and supporting all our customers so every installation proceeds as smoothly as possible. Most
installations offer their own unique challenges; we hope by making you aware of the following handling and installation guidelines you are empowered with knowledge
for a successful installation. As always, your Evo-Lite Systems Integration Specialist or any of our staff are ready to assist you with any questions that arise during your
installation.
FOLDING &
MINIMUM RADIUS
There is no minimum bending radius for Auragami Light Sheets, however a single sheet may not be
folded on itself because this could disrupt the flow of electricity through the folded sheet. Two separate
IP65 sheets may be attached back-to-back since the 3M adhesive backing will act as non-conductive
barrier. Light Sheets are not recommended for applications where a radius of less than 2” exists.
CUTTING
DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE SHEET IN ANY WAY.
NEVER CUT
AURAGAMI LIGHT SHEET WHILE POWERED. Field cutting of the Light Sheet does not void UL Listing. LEDs
can lose input power if cut lines are not followed. Avoid cut edge contact with any conductive material(s),
including other cut edges of Light Sheets. See also Wet Location Use below.
SOLDERING
DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE SHEET IN ANY WAY.
Solder sheets or
strips of Auragami together or solder power input(s) to Light Sheets. The Light Sheet’s copper pads are
engineered to handle 4 A of load and polarity is noted by the + and - next to each copper pad. Use 20
AWG stranded copper wire for up to 4 A of load and follow electronics soldering best practices.
FASTENING
USE PAN HEAD, DOMED, OR ROUND HEAD FASTENERS, NOT TAPERED SCREWS.
Never screw the
fastener so much that it deforms the Light Sheet. Only penetrate the Light Sheet within the smallest
of the two concentric circles marked on the sheet (see Drilling above for screw size limitations). For
suspended applications, use mechanical fasteners with an appropriate spacing to avoid sagging.
WET LOCATION
USE
Auragami Light Sheets are rated IP65. This rating is total protection against dust ingress as well as water
projected by a nozzle against the enclosure from any direction for a limited time and may be used in wet
locations, but not where standing water can accumulate. Cut edges of IP65 can optionally be sealed from
moisture with an RTV Silicone Sealant or conformal coating.
IP65
POWER, CONTROL
& WIRING
For optimal power distribution and to minimize voltage drop, it is recommended that multi-strand, high
strand count wiring be used for all low voltage DC connections. Wire gauge should be appropriate based
upon system voltage and wire lengths to further minimize voltage drop. Power supplies, drivers and
controls should be installed in well ventilated enclosures and/or per manufacturers recommendations.
It is the customer’s responsibility to ensure all components and installation practices meet or exceed
local codes and requirements.
Auragami® is a patented product of Evo-Lite, LLC. For more information please visit