background image

7.         If you have ordered a luminaire with an FAO (Field Adjustable Output switch) installed and you intend to 
 

use this to set a lower wattage, do so at this time if you have not done so already. Please refer to the RX1

 

datasheet for details. 

8. 

Rotate the photocontrol socket if position requires adjustment. By default, North is oriented to the front of 

 

the luminaire. Use a #2 Philips screwdriver for photocontrol socket or photocontrol only if rotation is

 

required. Torque to 25 in-lbs. 

9. 

Insert a twist lock photocontrol (not provided) or network node (not provided) into the photocontrol socket 

 

and install in accordance with the manufacturer’s instruction. 

10. 

Close the access panel. Tighten the access panel knob. Do not over tighten.

11. 

With power on, test the photocontrol. 

 

Note: Photocontrols and photocontrol test response times may vary. Some photocontrols may turn the 

 

light off and on over the first few minutes after power is applied. This does not indicate a defect. A

 

defective photocontrol will operate with the light on at all times regardless of the time of day. Allow several 

 

minutes for the photocontrol to turn the fixture off. A small number of photocontrols fail off. Test according 

 

to the type of photocontrol in use.

 

If the luminaire comes with the Evluma integrated photocontrol, “XP” model, allow up to 5 seconds for the 

 

luminaire to respond.

PHOTOCONTROL FAILSAFE

 
If the RoadMax has been ordered with Photocontrol Failsafe the luminaire will flash once to indicate that power is 
connected, and luminaire is in operation. The RoadMax begins collecting data immediately.  Short daytime tests of 
the photocontrol will not affect the gathering of this data.

WARRANTY

Warranty information may be found at evluma.com.
Components inside the fixture are not serviceable.

Copyright © 2022 Express Imaging Systems, LLC. Evluma, RoadMax, ConnectLED, and Photocontrol Failsafe are trademarks of Express Imaging Systems, LLC.  All rights reserved.   Content is subject to 
change. MET labs logo is a registered trademark of MET labs.

NEED ASSISTANCE?

Please feel free call us at 425-336-5800 M-F, 8pm- 4pm PST, or email [email protected].

Отзывы: