2.3 Technical data
ModuSat FS 80 & 150
Electrical
ModuSat FS 80
ModuSat FS 150
Electric supply
220/240 Volt (AC)
Frequency
50 Hz
Current absorption
(Without immersion Heater)
0.6A
Optional immersion heater
220/240 Volt (AC)
Hydraulic connections
ModuSat FS 80
ModuSat FS 150
Primary circuit supply
¾” ext. thread
Primary circuit return
¾” ext. thread
Apartment circuit supply
¾” ext. thread
Apartment circuit return
¾” ext. thread
DHW supply
¾” ext. thread
DCW inlet
¾” ext. thread
Hydraulic characteristics
ModuSat
FS 80
ModuSat FS 150
Max primary temperature
80 °C
Max primary pressure
10 bar (Optional 16 bar)
Recommended max apartment circuit cold fill pressure
1.5 bar
Max water supply pressure
16 bar
Pressure reducing valve fixed outlet pressure
3 bar
Max DHW storage tank pressure
8 bar
Internal unvented kit pressure relief valve setting
6 bar
PT relief valve setting
7 bar – 90 °C
Nominal DHW storage tank pressure
3.5 bar
Secondary heating circuit expansion vessel size
8 Litres
DWH storage capacity
80 l
150 l
Weight
ModuSat FS 80
ModuSat FS 150
Shipping Weight
97.5 kg
120 kg
Weight (full load)
177.5 kg
270 kg