background image

Every Contr

ol S.r

.l. • FK 203T • Sheet 2/2

The instrument shows the indications above flashing.

7

TECHNICAL DATA

7.1 Technical data

Box:

 self-extinguishing grey.

Size:

 75 x 33.5 x 81 mm (2.95 x 1.31 x 3.18 in) the model with extractable terminal

blocks (standard model), 75 x 33.5 x 62 mm (2.95 x 1.31 x 2.44 in) the model with

screw terminal blocks (by request).

Installation:

 panel mounting, panel cut out 71 x 29 mm (2.79 x 1.14 in), with click

brackets (they are supplied by the builder) or screw brackets (by request).

Frontal protection:

 IP 65.

Connections:

 extractable terminal blocks with pitch 5 mm (0.19 in, standard model)

for cables up to 2.5 mm² (0.38 sq in, power supply, inputs and outputs) or screw termi-

nal blocks with pitch 5 mm (0.19 in, by request) for cables up to 2.5 mm² (0.38 sq in,

power supply, inputs and outputs), 5 poles single line male connector with pitch

2.5 mm (0.09 in, serial port).

Ambient temperature:

 from 0 to 55 

°

C (32 to 131 

°

F, 10 ... 90% of relative humidity

without condensate).

Power supply:

 230 Vac, 50/60 Hz, 1.5 VA (standard model) or 115 Vac, 50/60 Hz,

1.5 VA (by request).

Measure inputs:

 2 (cabinet and evaporator probe) for PTC or NTC probes.

Working range:

 from -50 to 99 

°

C (-58 to 210 

°

F) for PTC probe, from -40 to 99 

°

C

(-40 to 210 

°

F) for NTC probe.

Setpoint range:

 from -55 to 99 

°

C (-55 to 99 

°

F).

Resolution:

 1 

°

F with unit of measure in Fahrenheit, 1 

°

C with unit of measure in

Celsius.

Display:

 one red LED 3-digit display 13.2 mm (0.51 in) high, output status indicators.

Outputs:

 3 relays: one 10 A @ 250 Vac relay for one ½ HP @ 230 Vac compressor

control (NO contact), one 8 A @ 250 Vac relay for evaporator fan control (NO contact)

and one 8 A @ 250 Vac relay for defrost system control (change-over contact).

Kind of defrost:

 electric and hot gas defrost.

Defrost control:

 defrost interval, defrost end temperature and defrost maximum length

(automatic and by hand).

cabinet

tem-

perature

lower or

upper

tempera-

ture alarm

the cabinet tempera-

ture is outside the limit

you have set with the

parameter A1 or A2

test the temperature

close to the probe

(look at the parameters

A0, A1 and A2)

no effects

Serial port:

 TTL with EVCOBUS communication protocol (for the configurer/cloner

system CLONE and supervision system RICS).

F6

0

1

---

0

kind of evaporator fan stop temperature (it is important if /A = 1 and F7 = 3 or 4;

0 = absolute evaporator fan stop temperature, 1 = evaporator fan stop temperature relative

to the cabinet temperature)

 (11)

F7

0

4

---

4

evaporator fan action during the normal operation (0 = it will be forced OFF, 1 = it will be

forced ON, 2 = it will work in accordance with the compressor, 3 = it will work in accordance

with F1 and F2, 4 = if the compressor is ON, it will work in accordance with F1 and F2, if the

compressor is OFF, it will be forced OFF)

LABEL MIN. MAX. U.M.

DEF. SERIAL NETWORK (EVCOBUS)

L1

1

15

---

1

instrument address

L2

0

7

---

6

instrument group

L4

0

3

---

1

baud rate (0 = 1,200 baud, 1 = 2,400 baud, 2 = 4,800 baud, 3 = 9,600 baud)

(4)

the unit of measure depends on the parameter /8

(5)

once you have modified the value of the parameter, you will have to switch off the power supply of the instrument

(6)

if the parameter has value 0, the defrost will end by time (parameter d3); if the parameter F7 has value 3 or 4, the evaporator fan will work in accordance with the compressor,

except what you have set with the parameters F4 and F5

(7)

unless the evaporator temperature is below the defrost end temperature you have set with the parameter d2, the defrost will not be activated

(8)

if at the moment of the defrost activation the cabinet temperature is below the value “working se r0” , the instrument will not show temperatures above that value; if

at the moment of the defrost activation the cabinet temperature is above the value “working se r0” , the instrument will not show the increases of the temperature (if

the increase takes place below the value “working se r0” , look at the previous case); the instrument restores the normal operation once the after dripping evaporator

fan delay ends and the cabinet temperature falls below the freeze temperature

(9)

if at the moment of the defrost activation the compressor is ON since a time lower than the one you have set with the parameter, the compressor will be forced ON for a

time such as to finish the time you have set with the parameter

(10) if the temperature alarm does not disappear at the end of the time you have set with the parameter A3, it will further be excluded for the time you have set with the parameter

A6; if the temperature alarm takes place during the defrost and does not disappear at the end of the time you have set with the parameter A7, it will further be excluded for the

time you have set with the parameter A6

(11) the evaporator fan stop temperature is “cabinet temperature - F1” ; you always have to consider the parameter F1 with positive sign.