4. Without bending or crimping the tubing, wet the free end of the tubing with water and push it into the
tank adapter valve approximately 5/8” until it stops. Secure connection with one of the included clips.
Step 8
Install Blue Tubing for Treated Water from Blue Outlet to Faucet
Note: Blue tubing (C5b) should already be installed in the blue outlet on the system head. Do not move forward
until ensuring you have completed Step 1 correctly.
1. Determine the length of blue tubing necessary to connect the outlet
to the threaded faucet stem, making sure to allow enough tubing to
prevent kinking in the line.
2. Cut the tubing squarely on the end not already connected to the
system head. Use a tubing cutter to ensure a square cut.
3. Gently slide the compression nut along the tubing. Press the plastic
ferrule into the blue tubing fully. The plastic compression sleeve
goes over the tubing, between the compression nut and faucet
stem.
4. Firmly push the tubing into the end of the threaded faucet stem,
hand-tightening the plastic compression nut onto the threads.
Tighten approximately ½ turn with an adjustable wrench.
Step 9
Install Drain Clamp Assembly and Red Drain Tubing
Note: Red tubing (C5d) should already be installed in the red drain outlet on the system head. Do not move
forward until ensuring you have completed Step 1 correctly.
1. Screw
1/4” hole into drain pipe under sink. Install clamp on side of pipe, as opposed to under pipe. This
ensures drain water flows properly and does not leak.
2. Determine the length of red tubing necessary to connect the outlet to the threaded drain clamp stem,
making sure to allow enough tubing to prevent kinking in the line.
3. Cut the tubing squarely on the end not already connected to the system head. Use a tubing cutter to
ensure a square cut.
4. Assemble drain clamp with tubing as shown in the
“Drain Clamp Assembly” illustration below.
5. Hand-tighten the plastic compression nut and then give it a 1/2 turn with an adjustable wrench
Содержание EVW-AZR-4RO
Страница 10: ......